W0109 마이크로 주사기펌프 |
|
[W0109 Series Micro Syringe Pumps] | |
|
| | | |
|
|
|
특 징 |
| |
|
규 격 |
+ 확대한 그림보기 -> |
TJ-3A/W0109-1B |
TS-1B/W0109-1B |
TJP-3A/W0109-1B |
Working Mode |
Infusion/Withdrawal |
Programmable |
Channel |
1 |
1~4 |
1 |
Syringe |
5 uL ~ 1.0 mL |
Stroke |
90 mm |
Pusher Advance |
0.165 um/step |
Linear Speed |
7.94 um/min ~ 79.4 mm/min |
Linear Resolution |
7.94 um/min |
Linear Accuracy |
≤±0.5% when ≥30% of pump stroke |
Linear Force |
≥9 kg (20 lbs) |
Syringe Selection |
Built-in syringe branched, size and inner diameters |
Syringe Defined |
Can store four user-defined syringe inner diamerters |
Flowrate Calibration |
Improve flowrate accuracy |
Running Parameter |
Dispensin volume can be each channel, all channel use the parameters of the specified channel |
Start setting |
Each drive unit can be started seperately, simultanously or according to each delay time |
Display Setting |
Display volume, flowrate or linear speed |
Power-off Memory |
Select keeping previous state or resetting parameters when power on |
Forwarard/backward |
Infuse or withrawal liquid at full speed |
State Output |
2 OC gate signal to indicate start/stop and direction |
Control Input |
3 TTL signal to control start/stop, fast forwarard and fast backward |
Communication |
RS-485 |
Drive unit dimension |
180 L x 46W x 78 mmH |
Drive unit weight |
0.6 kg |
Controller dimension |
170Lx108Wx65mmH |
235Lx178Wx74mmH |
170Lx108Wx65mmH |
Controller weight |
0.5 kg |
0.8 kg |
0.5 kg |
Power |
AC 90-260V/10W |
AC 90-260V/40W |
AC 90-260V/10W | |
Syringe |
Diameter (mm) |
Flowrate (uL/min~mL/min) |
1 mL |
4.72 |
0.139-1.39 |
2 mL |
9.00 |
0.505-5.05 |
5 mL |
13.10 |
1.07-10.7 |
10 mL |
16.60 |
1.718-17.18 |
20 mL |
19.00 |
2.251-22.51 |
30 mL |
23.00 |
3.298-32.98 |
60 mL |
29.14 |
5.295-52.95 | | |
|
주문정보 |
Model |
Product code |
Channel |
Pusher Advance |
Linear Force |
TJ-3A/W0109-1B |
050312A/050302A |
1 |
0.156 um/step |
≥9 kg (20 lbs) |
TS-1B/W0109-1B |
050317B/050302A |
1~4 |
TJP-3A/W0109-1B |
050313A/050302A |
1 | | |
|
기술자료 |
Programmable Syringe Pump TJP-3A Flow Rates Calibration (Release Time:2017-01-20)
Flow calibration: Operator can get more accurate flow through calibratingthe diameter of syringe barrel.
In work interface and stop state, press RCS to enter menu setting interface,turn RCS to highlight “Calibration”, press RCS to enter next interface, the first line display the programmed flow in current mode; the second line displays the testing time whose range is from 1 to 60 minutes. The third line displays theoretical volume (the product of flow and testing time) or input measured volume directly. The fourth line displays the start/stop and direction state.
Calibration procedure: set testing time first, start pump. Pump automatically stop after the testing time is over, measure the liquid volume and input the measured volume, the calibration is over. If knew the measured volume in advance, operator can directly input the measured volume.
|
Programmable Syringe Pump TJP-3A External Control (Release Time:2017-01-20)
Control the Start/Stop of the pump by external signal, the trigger and gate modes are optional.
In work interface and stop state, press RCS to enter menu setting interface turn RCS to highlight “EXT control”, press RCS to enter external start/stop mode setting interface. Press RCS again to select “Trigger” or “Gate”, press RCS to save the setting. | |
| |
|
|
|
귀하의 성공적인 연구개발의 동반자가 되겠습니다. |