규 격 | + 확대한 그림보기 -> | TJ-1A/L0107-1A  | TS-1A/L0107-1A  | TJ-2A/L0107-2A  | TS-2A/L0107-2A
 | Working Mode | Infusion | Infusion/Withdrawal | Channel | 1 | 1~4 | 1 | 1~4 | Syringe | 5 uL ~ 1.0 mL | Stroke | 70 mm | Pusher Advance | 0.165 um/step | Linear Speed | 7.94 um/min ~ 79.4 mm/min | Linear Resolution | 7.94 um/min | Linear Accuracy | ≤±0.5% when ≥30% of pump stroke | Linear Force | ≥2 kg (4.4 lbs) | Syringe Selection | Built-in syringe branched, size and inner diameters | Syringe Defined | Can store four user-defined syringe inner diamerters | Flowrate Calibration | Improve flowrate accuracy | Running Parameter | Dispensin volume can be each channel, all channel use the parameters of the specified channel | Start setting | Each drive unit can be started seperately, simultanously or according to each delay time | Display Setting | Display volume, flowrate or linear speed | Power-off Memory | Select keeping previous state or resetting parameters when power on | Forwarard/backward | Infuse or withrawal liquid at full speed | State Output | 2 OC gate signal to indicate start/stop and direction | Control Input | 3 TTL signal to control start/stop, fast forwarard and fast backward | Communication | RS-485 | Drive unit dimension | 180L x 46W x 78 mmH | Drive unit weight | 0.6 kg | Controller dimension | 170Lx108Wx65mmH | 235Lx178Wx74mmH | 170Lx108Wx65mmH | 235Lx178Wx74mmH | Controller weight | 0.5 kg | 0.8 kg | 0.5 kg | 0.8 kg | Power | AC 90-260V/10W | AC 90-260V/40W | AC 90-260V/10W | AC 90-260V/40W |
| Syringe | Diameter(mm) | Flowrate (nL/min~uL/min) | 5 uL | 0.35 | 0.764 - 7.64 | 10 uL | 0.50 | 1.559 - 15.59 | 25 uL | 0.80 | 3.991 - 39.91 | 50 uL | 1.10 | 7.546 - 75.46 | 100 uL | 1.60 | 15.96 - 159.6 | 250 uL | 2.30 | 32.99 - 329.9 | 500 uL | 3.25 | 65.87 - 658.7 | 1000 uL | 4.61 | 132.5 - 1325 |
|
|
|
주문정보 | Model | Product code | Channel | Pusher Advance | Linear Force | TJ-1A/L0107-1A | 050310A/050300A | 1 | 0.165 um/step | ≥2 kg (4.4 lbs) | TS-1A/L0107-1A | 050315B/050300A | 1~4 | TJ-2A/L0107-2A | 050311A/050301A | 1 | TS-2A/L0107-2A | 050316B/050301A | 1~4 | TJ-4A/SL0104A-1A | 050314A/050303A | 1 | 3.048 um/step | ≥1 kg (2.2 lbs) | TJ-4A/SL0107A-1A | 050314A/050304A | 1 |
| TJ-4A for Micromanipulator
 |
|
|
기술자료 | 
| 
| TJ-2A/L0107-2A 주사기펌프 조립 | TJ-2A 주사기펌프 유량교정 | 
| 
| TJ-2A 주사기펌프 분주모드 조작 | TJ-2A 주사기펌프 기본조작 | 
| 
| TS-1A 주사기펌프 멀티채널 동시작동 | TS-1A 주사기펌프 외부제어 | 
| 
| TS-1A 주사기펌프 멀티채널 작동 | TS-1A 주사기펌프 유량교정 |
|
|
|
|