본문 바로가기

브랜드별펌프/LONGER

튜브연동펌프 부속품[Peristaltic Pump Accessories] #롱거 #Longer #롱거펌프 #펌프부속품

최대 규모 Longer 공식 대리점 동방하이테크상사

#정식수입 #공식수입 #롱거펌프 #Longer Pump #견적문의 #펌프견적 #024576292

튜브연동펌프 부속품[Peristaltic Pump Accessories]
Dispensing Controller
Foot Switch
External Control Module

Dispensing Controller

Dispensing time 0-99.99S
 Pause time 0-99.99S
 Time resolution 0.01S
 Work mode Single or multiple
 Internal count range 0-999, count up or count down
 External count range 999999,0 means unlimited cycle
 External Start/Stop Open circuit
 Memory function Repower the pump, user can choose whether to continue in accordance with the state before the power-down
 Power supply AC 220V/5W
Type Product code Function
FK-1C 05.49.25A Dispensing controller can be equipped with many peristaltic pumps, gear pumps to realize dispensing automatically.

Foot Switch

Type

Product code

Connector

Applicable

Function

JK-1

05.49.20A

DB-9

Peristaltic
Pumps

Gated: Pump stops when it is powered on. Pump runs when press down the footswitch; and pump stops when release the footswitch.
Trigger: Pump stops when it is powered on. Pump runs when footswitch is pressed once, and pump will stop when footswitch is pressed again.

JK-2

05.49.20B

DB-9

Dispensing
Controller

Trigger: Pump stops when it is powered on. Pump runs when footswitch is pressed once, and pump will stop when footswitch is pressed again.

JK-3

05.49.20C

DB-15

Peristaltic
Pumps

Gated: Pump stops when it is powered on. Pump runs when press down the footswitch; and pump stops when release the footswitch.

JK-4

05.49.20D

DB-9

LSP Syringe
Pumps

Gated: Pump stops when it is powered on. Pump runs when press down the footswitch; and pump stops when release the footswitch.
Trigger: Pump stops when it is powered on. Pump runs when footswitch is pressed once, and pump will stop when footswitch is pressed again.

JK-5

05.49.20E

DB-15

TJ Syringe
Pumps

Trigger: Pump stops when it is powered on. Pump runs when footswitch is pressed once (press down and release), and pump will stop when footswitch is pressed again. 

JK-6

05.49.20F

None

TS Syringe
Pumps

Trigger: Pump stops when it is powered on. Pump runs when footswitch is pressed once (press down and release), and pump will stop when footswitch is pressed again. 

JK-8

05.49.20H

9-pin

YT600-1J

 

JK-9

05.49.20I

9-pin

WT600-3J

 

JK-10

05.49.20J

9-pin

WT600-4F

 

JK-11

05.49.20K

DB-15

Peristaltic
Pumps

 

JK-12

05.49.20L

DB-9

Peristaltic
Pumps

 

JK-13

05.49.20M

None

FK-100Z

 

JK-14

05.49.20N

BNC

LLP01-100

 

 External Control Interface

Type

Product code

Connector

BQ50-1J, WT3000-1JA, BT100-2J, BT100-1F, WT3000-1FA, BT300-2J, BT300-1F, WT3000-1JB, BT600-2J, WT600-2J, WT3000-1FB, WT600-1F

0~5 V

05.49.31A

DB-15

0~10 V

05.49.31B

DB-15

4~20 mA

05.49.31C

DB-15

0~10 kHz

05.49.31D

DB-15

RS-485

05.49.31E

DB-15

WK-01

-

-

Change (4-20mA, 0-5V, 0-10V) on the basis of standard analog external control module on the increase in internal and external control conversion.

Wk-02

-

-

Switching control start and stop supporting OEM100J-75

WK-03

-

-

Switching control start and stop supporting OEM100J-75

WK-04

-

-

Switching control peristaltic pump (except aeronautical product plug interfaces) start and stop, stop short, disconnected operation

WK-05

-

-

Switching control peristaltic pump WT600-3J, WT600-4F start and stop

WK-06

-

-

Switching control start and stop, fault alarm output by the extraction module

WK-07

-

-

WK-04 module controls the start and stop logic is inverted; short run, stop off

WK-08

-

-

External control only controls the start and stop buttons control the speed of the internal control, 5V stopped, suspended the operation according to the original state

WK-09

-

-

External control only controls the start and stop buttons control the speed of the internal control, 24V stopped, suspended the operation according to the original state

WK-10

-

-

External control switch start and stop and direction control, speed control button internal, supporting BT100-2J-12 & YZ1515X

WK-11

-

-

Increase external control switch function on the basis of external control 0-10V

WK-12

-

-

And supporting the use of BT100-2J-18, DB15 connected to drive external control interface, DB9 pin 2 Take 0-10V negative, positive needle 5 then 0-10V

WK-17

-

-

Adaptation LSP02-1B-1, by switching control and direction of the pump start and stop.

WK-18

-

-

Supporting BT100-2J-21

WK-19

-

-

Supporting the use TJ-3A-5, switch control, external control start and stop and direction control

◈기술자료

BT100-2J 펌프 외부제어

BT600-2J 펌프 외부제어(0-5V)

BT600-2J 펌프 PC제어

LEAD-2 펌프 외부제어

 

 