뛰어난 성능과 신뢰성의 Analytical Scientfic Instruments(ASI) 공식대리점
#정식수입 #공식인증 #ASI제휴 #ASI액체크로마토그래피 #ASI제품문의 #ASI연구기기 #동방하이테크상사
HPLC 부속품 [HPLC Accessories]t |
||
》 펄스댐퍼 (Pulse Damper) 》 체크밸브 (In-line Check Valve) 》 핏팅, 유니온 (Fittings and Unions) 》 필터 (Filter) 》 시료주입기 (Injectio Valve) 》 고압 정량밸브 (High Pressure Metering Values) 》 튜빙(Tubing) |
◈펄스댐퍼 (Pulse Damper)
The ASI FlatLine™ Pulse Damper combines performance and reliability in a simple, easy to use housing. Standard 10-32 inlet and outlet ports allow quick connection into virtually any HPLC system. Solid core technology provides reliable long term operation without the down time associated with ruptured or leaking membrane dampers. Custom sizes and additional features like integral prime/purge valve available for the OEM market. Although similar to the standard ASI FlatLine™ Damper, the HC (High Capacity) features a bimodal damping mechanism which includes solid core and dynamic spring deflection. This combination increases damping efficiency over a wider pressure range. The HC is particularly well suited for damping at low pressures, below 500 PSI. |
특 징 |
주문정보 |
ASI Part Number |
ASI FlatLine™ Pulse Damper |
590-0001 |
ASI FlatLine™ HC Pulse Damper |
590-0010 |
◈체크밸브 (In-line Check Valve)
The ASI in-line check valve incorporates many of the innovations of our self-priming replacement check valves. It is a rapid closure cartridge valve that features very low resistance to flow, low internal volume, and operates independently of gravity. It is protected from solvent contamination by a 1/4" diameter 2 micron frit, and features crush-proof construction. The valve may be used whenever fluid flow needs to be restricted to one direction. Applications include prevention of post column derivitization fluids from back-flowing into the column in the event of mobile phase pump failure. This valve is also available in a high temperature version that will operate at up to 125º C and 5000 PSI. (Please call for more information). |
규 격 |
Internal |
Cracking |
Maximum |
Cv* |
250-2000 In-Line CV Assembly |
48 µL |
1.0 PSI |
15,000 PSI |
0.005 |
250-2006 In-Line CV Cartridge |
||||
250-2000UHP In-line CV Assembly |
48 µL |
1.0 PSI |
30,000 PSI |
0.005 |
250-2000UHP In-line CV Cartage |
||||
250-2001 In-line CV Assembly |
60 µL |
1.0 PSI |
15,000 PSI |
0.02 |
250-2001 In-line CV Cartage |
||||
*Cv of 1.0 is defined as one gallon per minute of 60 °F water resulting from a 1 PSI pressure drop. 1 gallon = 3,785 mL. |
주문정보 |
ASI Part Number |
In-Line Check Valve with 1/8" Ball Cartridge |
250-2000 |
Replacement 1/8" Ball Cartridge |
250-2006 |
In-Line Check Valve with 1/8" Ball Cartridge Ultra High Pressure |
250-2000UHP |
Replacement 1/8" Ball Cartridge Ultra High Pressure |
250-2006UHP |
In-Line Check Valve with 3/16" Ball Cartridge |
250-2001 |
Replacement 3/16" Ball Cartridge |
250-2007 |
◈핏팅, 유니온 (Fittings and Unions)
Universal fittings and unions are compatible with most HPLC fittings such as Parker, Swagelok, Valco, Upchurch, Beckman, and Waters, when initially assembled with new ferrules. All components are manufactured from 316 stainless steel, and are cleaned and passivated. Unions come complete with 1/16" compression fittings. |
주문정보 |
ASI Part Number |
ZDV Straight Union 0.040” Thru |
920-0624 |
ZDV Straight Union 0.020” Thru |
920-0622 |
10-32 Compression Screw 1/16” Tube 10/Pack |
900-0622 |
10-32 Compression Screw 1/16” Tube 25/Pack |
900-0623 |
Ferrule for 1/16" Tube 10/Pack |
910-0622 |
Ferrule for 1/16" Tube 25/Pack |
910-0623 |
PEEK Fingertight Fittings for 1/16” TFE, PEEK Tube |
800-0630 |
PEEK Fingertight Fittings for 1/16” TFE, PEEK Tube 10/Pack |
800-0631 |
◈필터 (Filter)
Solvent Filters |
|
It is essential to use a solvent filter at the pump intake to insure reliable operation of the check valves and other pump system components. We recommend a 10 micron filter for most analytical applications. For flow rates in excess of 10 mL per minute, we recommend a 20 micron filter to avoid pump cavitation. ASI filters are designed to slip inside either 1/16" ID or 1/8" ID tubing, and are made from 316 stainless steel. |
주문정보 |
ASI Part Number |
10 micro Solvent Filter for 1/16" ID |
850-0620 |
10 micro Solvent Filter for 1/16" ID 5/Pack |
850-0621 |
10 micro Solvent Filter for 1/8" ID |
850-1250 |
10 micro Solvent Filter for 1/8" ID 5/Pack |
850-1251 |
20 micro Solvent Filter for 1/8" OD |
850-1248 |
20 micro Solvent Filter for 1/8" OD 5/Pack |
850-1249 |
ColumnShield Precolumn Filter |
|
PrimeLine ColumnShield precolumn filter provides economical protection from the harmful effects of sample and mobile phase particulates on modern HPLC columns. The disposable filter was engineered to maintain the efficiency of high performance columns assuring insuring no loss of critical resolution. With its simple design, the filter installs in any analytical column or guard column in seconds and is leak tight to 5,000 PSI. To install simply hand tighten the filter as you would with any fingertight fitting while holding the column stable. |
특 징 |
Economical protection against micro-particles |
Extends HPLC column lifetime |
Negligible effect on column performance |
Universal fit, connects directly to column |
Fingertight to 5,000 PSI |
규 격 |
|
Inlet/Outlet |
: Female/Male 10-32 |
Port Geometry |
: Parker (1/16 CPI) |
Material |
: PEEK |
Filter |
: 0.5 micron Titanium |
Pressure Rating |
: 5,000 psig |
Fingertight |
: No wrenches required |
주문정보 |
ASI Part Number |
ColumnShield Precolumn Filter, 0.5 micron |
850-1050 |
ColumnShield Precolumn Filter, 0.5 micron, 5/Pack |
850-1050-05 |
ColumnShield Precolumn Filter, 0.5 micron, 10/Pack |
850-1050-10 |
In-Line HPLC/UHPLC Filters | |
Placed between the pump and injector, these filters protect the injector from pump seal wear material and extend the life of the column prefilter. All filters are made from 316 stainless steel and are rated to 6,000 PSI. Filters for UPLC are rated to 15,000 PSI. All male/female ports are compatible with 10-32 compression fittings. | |
High Capacity In-Line Filters |
Low Volume In-Line Filters |
High Capacity In-Line Filters | |
This filter features a clean-swept internal volume and a large 2.2 cm2 filter area that will provide a long service life. Filter cartridges are available in 0.5 micron and 2 micron porosity,and are both interchangeable and replaceable. Total internal volume is 100 μL for 0.5 micron filter, and 120 μL for 2 micron filter. | |
주문정보 | ASI Part Number |
High Capacity In-Line Filter Assembly, 2 micron | 850-1310 |
High Capacity In-Line Filter Assembly, 2 micron, HP | 850-1310HP |
ColumnShield Precolumn Filter, 0.5 micron, 10/Pack | 850-1050-10 |
High Capacity In-Line Filter Assembly, 0.5 micron | 850-1315 |
High Capacity In-Line Filter Assembly, 0.5 micron, HP | 850-1315HP |
2 micron Replacement Filter Cartridge for HC | 850-1320 |
0.5 micron Replacement Filter Cartridge for HC | 850-1325 |
Low Volume In-Line Filters |
Recommended for applications where system volume must be kept to a minimum. Full use of the filter surface is maintained by a 5° entrance cone. The 0.25” diameter replacement filter cartridges are available in 0.5 micron and 2 micron porosity, and have a 0.32 cm2 active area. Total internal volume is 14 μL for the 0.5 micron filter and 18 μL for the 2 micron filter. The 0.062” replacement filter is 0.5 micron with 2 μL internal volume. |
주문정보 |
ASI Part Number |
High Capacity In-Line Filter Assembly, 2 micron |
850-1310 |
High Capacity In-Line Filter Assembly, 2 micron, High Pressure |
850-1310HP |
ColumnShield Precolumn Filter, 0.5 micron, 10/Pack |
850-1050-10 |
High Capacity In-Line Filter Assembly, 0.5 micron |
850-1315 |
High Capacity In-Line Filter Assembly, 0.5 micron, High Pressure |
850-1315HP |
2 micron Replacement Filter Cartridge for HC |
850-1320 |
0.5 micron Replacement Filter Cartridge for HC |
850-1325 |
In-Line & Direct Connect HPLC/UHPLC Column Filters |
PrimeLine direct connect precolumn filters provide economical protection from the harmful effects of sample and mobile phase particulates on modern HPLC and UHPLC columns. The PrimeLine precolumn filter was engineered specifically for use in high throughput and routine HPLC separations where mobile phase and sample contamination cause a decrease in column performance or premature column failure. The low swept volume of the PrimeLine filter maintains the efficiency of high performance columns assuring a negligible loss of critical resolution. With its simple design, the PrimeLine filter installs in any analytical column in seconds and is leak tight to 15,000 PSI. Simply finger tighten initially, then wrench tighten an additional 1/4 - 1/2 turn. |
In-line Filter |
Direct Connect Column Filter |
특 징 |
Cost effective way to extend column lifetime |
Replaceable filter element |
Negligible effect on column performance |
Universal fit, connects directly to column |
Leak tight to 15,000 PSI |
주문정보 |
ASI Part Number |
In-Line Filter Assembly, 0.5 micron |
850-1025 |
Direct Connect Column Filter Assembly, 0.5 micron |
850-1020 |
0.5 micron .125" dia. x .062" Replacement Filter Assembly, 5/Pack |
850-1020-01 |
UltraShield HPLC/UHPLC Precolumn Filter |
|
UltraShield direct connect precolumn filters provide economical protection from the harmful effects of sample and mobile phase particulates on modern UHPLC and other high resolution HPLC columns. UltraShield was engineered specifically for use in fast, high efficiency separations requiring high mobile phase velocities and ultra high pressure. UltraShield maintains the efficiency of these high performance columns assuring no loss of critical resolution. With its simple design, UltraShield installs in any analytical column in seconds and is leak tight to 15,000 PSI. Simply tighten the filter with a wrench until it is snug, followed by an additional 1/4 turn. |
규 격 |
|
Inlet/Outlet |
: Female/Male 10-32 |
Port Geometry |
: Parker (1/16 CPI) |
Material |
: Stainless Steel, PEEK ferrule |
Filter |
: 0.5 micron Titanium |
Pressure Rating |
: 15,000 psig |
Wrench Flat |
: 5/16” |
주문정보 |
ASI Part Number |
UltraShield Precolumn Filter Assembly |
850-1010 |
UltraShield Precolumn Filter Assembly, 5/Pack |
850-1010-05 |
UltraShield Precolumn Filter Assembly, 10/Pack |
850-1010-10 |
Guard Column HPLC/UHPLC Hardware |
|
The PrimeLine direct connect guard column provides economical protection from the harmful effects of sample and mobile phase particulates and soluble contaminants on modern HPLC and UHPLC columns. The low swept volume of the PrimeLine guard column maintains the efficiency of high performance columns assuring a negligible loss of critical resolution. With its simple design, the PrimeLine guard column installs in any analytical column in seconds and is leak tight to 10,000 PSI. |
주문정보 |
ASI Part Number |
Guard Column Housing |
850-1390 |
Guard Column Assembly, 2 mm x 10 mm |
850-1392 |
Guard Column Assembly, 4 mm x 10 mm |
850-1394 |
◈시료주입기 (Injection Valve)
WX-100 Manual Injection Valve |
|
The WX-1000 manual injection valve is a traditional 6 port two position flat face shear valve with a front loading needle port, designed for use in traditional HPLC chromatography systems. |
특 징 |
Compatible with Rheodyne 7725i spare parts |
Pmax 5,000 PSI adjustable to 7,000, Temperature 80°C |
Uninterruptable (non-pulsing) flow during switching |
Self adjusting stator seal for easy maintenance |
Improved ceramic stator seal to eliminate wear and carry over |
주문정보 |
ASI Part Number |
Manual Injection Vavle,WX-1000-01 Kit, includes 20 µL loop |
A500-1017 |
Valve rebuild Kit,WRX-1000 |
500-1017-RKIT |
VS Rotor Seal |
500-1017-RS |
WX-1000 Stator, SS |
500-1017-STS |
Stator Face Assembly |
500-1017-STF |
5 µl SS Sample loop, 30° |
500-1017-05 |
10 µl SS Sample loop, 30° |
500-1017-10 |
20 µl SS Sample loop, 30° |
500-1017-20 |
100 µl SS Sample loop, 30° |
500-1017-100 |
◈고압 정량밸브 (High Pressure Metering Valves)
The High Pressure Adjustable Metering Valve maintains a back pressure which is directly proportional to the inlet flow rate and solvent viscosity. The valve has an adjustment range from 10 PSI to 5,000 PSI at 1.00 mL/min. with water. The dead volume is less than 4 µL with flow paths designed to minimize dispersion. |
주문정보 |
ASI Part Number |
High Pressure Metering Valve |
690-0000 |
◈튜빙(Tubing)
1/16 " OD Stainless Steel Capillary |
|
ASI Capillary tubing is made from 316 stainless steel and is available in 25 ft. lengths; other lengths upon request. The tubing ID should be passivated after cutting as follows: 20 % nitric acid for 30 minutes, followed by distilled water rinse. |
|
Teflon (TFE) Tubing |
|
Teflon Tubing provides unmatched solvent resistance for low pressure applications. |
|
PEEK Tubing |
|
PEEK can be substituted for stainless steel tubing when contact with metal is a concern. It is inert to most HPLC solvents, will withstand intermittent operation up to 5,000 PSI, and continuous operation at 4,000 PSI. PEEK tubing should not be used at these pressures with DSMO,THF, or methylene chloride. |
주문정보 |
ASI Part Number |
SS Tubing 1/16” OD x 0.010” ID x 25 ft |
800-0010 |
SS Tubing 1/16” OD x 0.020” ID x 25 ft |
800-0020 |
Teflon (TFE) Tubing 1/16” OD x 0.030” ID x 25 ft |
810-0030 |
Teflon (TFE) Tubing 1/8” OD x 1/16” ID x 25 ft |
810-0063 |
Teflon (TFE) Thinwall Tubing 1/8” ID x 25 ft |
810-0125 |
PEEK Tubing 1/16” OD x 0.005” ID x 5 ft |
820-0631 |
PEEK Tubing 1/16” OD x 0.010” ID x 5 ft |
820-0632 |
PEEK Tubing 1/16” OD x 0.020” ID x 5 ft |
820-0630 |
귀하의 성공적인 연구개발의 동반자가 되겠습니다.
***************************************************************************************
동방하이테크상사
http://www.allpump.co.kr
서울시 성동구 광나루로6길 35, 성수이비즈센터 710호
T)02-457-6292 F)457-6293 dbht@allpump.co.kr
***************************************************************************************
정량펌프, 정밀펌프, 고압펌프, 마이크로펌프, OEM 펌프, HPLC 펌프, 피스톤펌프, 주사기펌프, 실린지펌프, 다이어프램펌프, 다이아프램펌프, 튜브펌프, 튜빙펌프, 호스펌프, 연동펌프, 기어펌프, 기아펌프, 플런져펌프, 부란자펌프, 초정밀펌프, 초미세펌프, 초고압펌프, 밸브, 피팅, 튜빙, 아답터, 크로마토그래피 제품, 연구실험기자재 등
'브랜드별펌프 > ASI' 카테고리의 다른 글
HyperShear™ 유체혼합기 #ASI펌프 #ASI HPLC #ASI액체크로마토그래피 (0) | 2020.06.08 |
---|---|
PrimeLine™ HPLC 펌프 교체부품 #ASI펌프 #ASI HPLC #ASI연구기기 (0) | 2020.06.08 |
Model310 컬럼후반응기(PCR) (0) | 2019.09.30 |
HyperShear™ 유체혼합기 (0) | 2019.09.30 |
[PrimeLine™ 정밀고압정량펌프, HPLC 펌프 [PrimeLine™ HPLC Pump] (0) | 2019.09.30 |