펌프전문가들이 극찬한 Longer Precision Pump Co.,Ltd. 공식대리점
#정식수입 #공식인증 #Longer제휴 #Longer펌프견적 #Longer펌프문의 #펌프견적문의 #동방하이테크상사
LSP 주입/흡입식 정밀 주사기펌프 [LSP Series Syringe Pumps] |
||
》 LSP02-1B 주입/흡입식 2-채널 주사기펌프 》 LSP10-1B 주입/흡입식 10-채널 주사기펌프 》 LSP01B-1BH 주입/흡입식 1-채널 고압주사기펌프 》 LSP01C-1C 푸쉬/풀식 2-채널 주사기펌프 |
◈개 요
LSP 주사기펌프는 설치와 작동이 간편하고 높은 정밀도와 신뢰성을 제공하는 실험실용 표준형 주사기펌프이다. |
주입전용 제품으로 공급되며, 10 µL에서 60 mL 주사기를 장착할 수 있다. |
대형 LCD 화면에서 회전스위치와 멤브레인키패드를 이용하여 파라메터의 설정을 간편하게 할 수 있다 |
◈특 징
Syringe Selection : The syringe can be selected in the manufacturer table which includes manufacturer, material and size or input the inner diameter of the syringe barrel directly |
Easy to operate: Combining big screen LCD display with rotary coded switch and membrane keypad makes the operation simple and prompt. |
Working Mode: Infusion, withdrawal, infusion/withdrawal, withdrawal/infusion, continuous |
Memory Function : 1. The parameters are saved in EEPROM. The parameters don't need to be reset when power returns after an interruption 2. In flow rate mode, the pump remains running or stop according to the setting parameters when power returns after an interruption |
Protection Function : The pump will stall and give an alarm when the drive structure of the pump is blocked |
Communication Function : Realize computer control through RS485 communication interface |
Calibration Function : Acquire accurate volume through calibration: Input/output control |
Syringe Protection : Adjust syringe rest to prevent syringe from damaging |
◈규 격
|
LSP02-1B |
LSP10-1B |
LSP01-1BH |
LSP01-1C |
Working Mode |
Infusion/Withdrawal |
Push/Full |
||
Channel |
2 |
10 |
1 |
2 |
Syringe |
10 uL ~ 60 mL |
10 uL ~ 10 mL |
10 uL ~ 100 mL |
10 uL ~ 10 mL |
Stroke |
140 mm |
|||
Pusher Advance |
0.156 um/step |
|||
Linear Speed |
5 um/min~130 mm/min |
5um/min~65mm/min |
||
Linear Resolution |
5 um/min |
|||
Linear Accuracy |
≤±0.5% when ≥30% of pump stroke |
|||
Linear Force |
≥18 kg (40 lbs) |
≥45 kg (99 lbs) |
≥9 kg (20 lbs) |
|
Syringe Selection |
Built-in syringe branched, size and inner diameters |
|||
Syringe Defined |
Can store four user-defined syringe inner diamerters |
|||
Flowrate Calibration |
Improve flowrate accuracy |
|||
Running Parameter |
Infusion/withdrawal volume, infusion/withdrawal time, pause time, etc |
|||
Display Setting |
Display volume, flowrate or linear speed |
|||
Power-off Memory |
Storing the running parameters automatically |
|||
State Output |
OC gate signal to indicate start/stop and direction |
|||
Control Input |
Falling edge or TTL signal to control Start/Stop |
|||
Communication |
RS-485 |
|||
Diemensin |
280Lx210Wx140mmH |
280Lx330Wx140mmH |
280Lx250Wx140mmH |
280Lx220Wx140mmH |
Weight |
4.3 kg |
5.3 kg |
6.3 kg |
3.6 kg |
Power |
AC 90-260V/20W |
AC 90-260V/25W |
AC 90-260V/15W |
Syringe |
Diameter |
LSP02-1B |
LSP10-1B |
LSP01-1C |
10 uL |
0.50 |
0.001-0.0255 |
0.001-0.0255 |
0.001-0.0128 |
25 uL |
0.80 |
0.0025-0.0653 |
0.0025-0.0653 |
0.0025-0.0327 |
50 uL |
1.10 |
0.0048-0.1235 |
0.0048-0.1235 |
0.0048-0.0618 |
100 uL |
1.60 |
0.0101-0.2614 |
0.0101-0.2614 |
0.0101-0.1307 |
250 uL |
2.30 |
0.0208-0.5401 |
0.0208-0.5401 |
0.0208-0.2701 |
500 uL |
3.25 |
0.0415-1.0784 |
0.0415-1.0784 |
0.0415-0.5392 |
1.0 mL |
4.72 |
0.0875-2.2747 |
0.0875-2.2747 |
0.0875-1.1373 |
2.0 mL |
9.00 |
0.3181-8.2702 |
0.3181-8.2702 |
0.3181-4.1351 |
5.0 mL |
13.10 |
0.6739-17.522 |
0.6739-17.522 |
0.6739-8.7608 |
10 mL |
16.60 |
1.0821-28.135 |
1.0821-28.135 |
1.0821-14.068 |
20 mL |
19.00 |
1.4176-36.859 |
- |
- |
30 mL |
23.00 |
2.0774-54.012 |
- |
- |
60 mL |
29.14 |
3.3346-86.699 |
- |
- |
Syringe |
Diameter (mm) |
LSP01-1C (uL/min~mL/min) |
Outlet Pressure (Mpa) |
2.5 mL |
4.79 |
0.0901-2.3426 |
19.48 |
8.0 mL |
9.53 |
0.3567-9.2730 |
5.05 |
20 mL |
19.13 |
1.4371-37.3648 |
1.25 |
50 mL |
28.6 |
3.2121-83.5152 |
0.56 |
100 mL |
34.9 |
4.7831-124.361 |
0.37 |
◈주문정보
Model |
Product code |
Channel |
Pusher Advance |
Linear Force |
LSP02-1B |
050344A |
2 |
0.156 um/step |
≥18 kg (40 lbs) |
LSP10-1B |
050346A |
10 |
0.156 um/step |
≥18 kg (40 lbs) |
LSP01-1BH |
050343A |
1 |
0.156 um/step |
≥45 kg (99 lbs) |
LSP01-1C |
050342A |
1 |
0.156 um/step |
≥9 kg (20 lbs) |
LSP01-1BH High Pressure Syringe Pump | |
SS syringe |
Tube length |
Stroke length |
Outer diameter |
Inner diameter |
Total length |
8 mL |
170 mm |
110.5 mm |
14 mm |
9.53 mm |
203 mm |
20 mL |
120 mm |
68.4 mm |
22 mm |
19.13 mm |
144 mm |
50 mL |
140 mm |
76.8 mm |
32 mm |
28.6 mm |
165 mm |
100 mL |
170 mm |
107.0 mm |
38 mm |
34.9 mm |
210 mm |
LSP01-1C Push/Full Syringe Pump | |
◈기술자료
LSP02(10)-1B Syringe Pump External control port (Release Time:2017-01-06) Pin definition 2 Directional output, OC gate output, open – infusion, close – withdrawal (stays open when stopped)
|
LSP02(10)-1B Syringe Pump RS485 setup (Release Time:2017-01-06) The RS485 connections are made through terminal connectors, located on the rear panel. A single PC can control up to 30 pumps. When controlled by a PC each pump must be assigned an individual address. When controlled via RS485 the pump will still respond to keypad commands. All RS485 commands settings, similar to keypad settings, are stored in EEPROM. When RS485 is enabled, RS485 interface will display communication address and band rate. The communication address is from 1 to 30. The default address is 1. The band rate is 1200 bps, 2400 bps and 9600 bps. The default band rate is 2400 bps. RS485 format: 1 start bit, 8 data bits, 1 even parity, 1 stop. For detailed RS485 commands please see <Longer’s RS485 Protocol for LSP>. In parameters setting interface, press and turn RES to highlight the RS485 line. Set RS485 enabled. The LCD displays communication address and band rate. Turn RES to make the address highlighted. Press RES to highlight the numerical value. Turn RES to set the communication address. Press RES again to confirm and save the setting. Turn RES to highlight the band rate. Press RES to make the numerical value highlighted. Turn RES to select the band rate. Press RES again to confirm and save the selection.
|
LSP02(10)-1B Syringe Pump External control function (Release Time:2017-01-06) External control function, including run/stop control input and direction control input can be enabled or disabled. 1. In parameters setting interface, press and turn RES to highlight the external control line. |
LSP02(10)-1B Syringe Pump Calibration (Release Time:2017-01-06) The flowrate can be calibrated for more accurate dispense volume. 1. In parameters setting interface, press and turn RES to highlight the Calibration line. Press RES to enter calibration interface. |
LSP02(10)-1B Dual Channels Syringe Pump Pause time setting (Release Time:2017-01-06) In infusion/withdrawal mode, the pause time is set in infusion parameters setting interface. In withdrawal mode, the pause time is set in withdrawal parameters setting interface. In continuous mode, the pause time need to be set both in infusion mode interface and in withdrawal mode interface. The unit of pause time is sec, i.e. second, and the range of pause time is from 0 to 9999sec in steps of 0.1sec |
LSP02(10)-1B Dual Channels Syringe Pump Flowrate setting (Release Time:2017-01-06) In parameters setting interface, turn and press RES to highlight the infusion flowrate or withdrawal flowrate setting line. Press RES to make the numerical value position highlighted. Enter the flowrate required from the membrane keypad. Press RES to set flowrate unit. Turn RES to scroll through the list and press RES to select the unit required. Possible flowrate units are µl /h, µl/m, ml/h, ml/m. The highlighted display indicates that this parameter can be changed. Note: If the number entered exceeds the maximum flowrate possible then the pump prompts the maximum feasible flowrate at the Time position. To continue enter a flowrate smaller than the maximum. |
LSP02(10)-1B Dual Channels Syringe Pump Volume setting (Release Time:2017-01-06) In parameters setting interface, turn and press RES to highlight the infusion volume or withdrawal volume setting line. Press RES to make the numerical value position highlighted. Enter targeted volume from the membrane keypad. Press RES to set volume unit. Turn RES to scroll through the list and press RES to select the unit required. Possible volume units are µl and ml, i.e. microliter and milliliter. The highlighted display indicates that this parameter can be changed. Note: When the volume setting is zero, Infusion or Withdrawal modes. |
LSP01-1BH 주사기펌프 압력시험 |
귀하의 성공적인 연구개발의 동반자가 되겠습니다.
***************************************************************************************
동방하이테크상사
http://www.allpump.co.kr
서울시 성동구 광나루로6길 35, 성수이비즈센터 710호
T)02-457-6292 F)457-6293 dbht@allpump.co.kr
***************************************************************************************
정량펌프, 정밀펌프, 고압펌프, 마이크로펌프, OEM 펌프, HPLC 펌프, 피스톤펌프, 주사기펌프, 실린지펌프, 다이어프램펌프, 다이아프램펌프, 튜브펌프, 튜빙펌프, 호스펌프, 연동펌프, 기어펌프, 기아펌프, 플런져펌프, 부란자펌프, 초정밀펌프, 초미세펌프, 초고압펌프, 밸브, 피팅, 튜빙, 아답터, 크로마토그래피 제품, 연구실험기자재 등
'브랜드별펌프 > LONGER' 카테고리의 다른 글
연동펌프 튜빙, 핏팅 [Peristaltic Pump Tubing & Fitting] (0) | 2020.09.18 |
---|---|
LSP 주입식 정밀 주사기펌프 [LSP Infusion Syringe Pumps] (0) | 2020.09.17 |
L0107 마이크로 주사기펌프 [L0107 Series Micro Syringe Pumps] (0) | 2020.09.16 |
W0109 마이크로 주사기펌프 [W0109 Series Micro Syringe Pumps] (0) | 2020.09.16 |
SP 공업용 OEM 주사기펌프[SP Series Industrial OEM Syringe Pumps] (0) | 2020.09.16 |