펌프전문가들이 극찬한 Longer Precision Pump Co.,Ltd. 공식대리점
#정식수입 #공식인증 #Longer제휴 #Longer펌프견적 #Longer펌프문의 #펌프견적문의 #동방하이테크상사
JL350-2J 대규모 튜브연동식 정량펌프 [JL350-2J Large Flow Peristaltic Tubing Pump] |
||
》 AC 모터, 주파수 변조 콘드롤 》 회전속도 : 30~350 rpm, 역회전, 》 유량범위 : 1.3~35 Liter/min 》 펌프헤드 : KZ48 |
◈개 요
JL350-2J 공업용 튜브연동식 정량펌프는 높은 유량으로 일괄유체이송에 적합하며, AC 모터와 주파수 변조기에 의해 회전속도를 제어할 수 있다. |
최대 35 Liter/min 까지 유량조절이 가능하며, 투명한 전면커버를 통해 펌프헤드의 작동상태를 관찰할 수 있다. |
펌프의 회전속도와 회전방향, 시작/정지 기능은 멤브레인 키패드에 의해 수동조작하거나 외부제어 인터페이스를 통해 자동으로 제어할 수 있다. |
조작이 간단하고 편리하다. |
◈특 징
Mainly used in industrial application. But also suitable for laboratory application where the high flow rate is required. |
JL350-2J peristaltic pump is ideal for high flow rates fluid transfer. The flow rate is from 1.3L/min to 15mL/min. The pump is driven by the AC motor, and the speed is controlled through the frequency converter. This pump is mainly for industrial application. |
High-capacity pump |
Combine special convex rollers with concave compression block to run stably and prolong tubing life. |
Variable frequency speed control to AC motor with creeper gear |
Adjustable occlusion |
Strong drive |
Pump head operation is visible through transparent front cover |
◈규 격
Speed |
30~350 rpm, CW/CCW |
Speed resolution | 0.6 rpm |
Speed control | Frequency converrtor, external signal control and communication control available |
Display | LCD for running information |
External control | Start/stop and cw/ccw control |
|
0~5V, 0~10V, 4~20mA & 0~10KHz linear control |
Communication interface |
RS485 or RS232 |
Memory function |
Storing the running parameter automatically |
Power supply | AC220V±10%/50-60 Hz |
Power consumption |
≤400W |
Operating condition | Temperature; 0~40℃ |
|
Relative humidity; <80% |
Dimensions | 417 L x 401 W x 321 mmH |
Weight | 32 kg |
IP rating | IP55 |
◈주문정보
Drive |
Pump head |
Tubing |
Flowrates(L/min) |
Weight(kg) |
JL350-2J |
KZ48 |
88# |
1.3~15 |
32 |
92# |
3~35 |
◈기술자료
JL350-2J Large Flow Rates Pump External Control Function (Release Time:2016-12-23)
External Control Function ; External analog signal controls the speed: The keys on the panel of frequency converter are invalid by setting the parameters (needs unlock). The speeds are controlled by external control terminals.485 communication interface: By setting the parameters (needs unlock) the master computer can control the pump directly by communication interface. Note; The frequency converter has many parameter setting items. To avoid misoperation we lock the parameter settings by password.We set the max. frequency of the frequency converter is 65 Hz and the max. speed is 370 rpm. If other parameters setting are needed please ask for password from our company. But we won't take any responsibility if damage occurs because of parameters changing.
|
Basic operation of the Frequency Converter for JL350-2J (Release Time:2016-12-23)
The LED display of frequency converter lights when the power supply switches on. But the pump is in stopping status.Run /stop: Press [Run/Stop] key, the [Run] indicator lights and the pump runs. Press the [Run/Stop] key again the pump stops.Speed Adjustment: Press Speed Adjustment/ Data Input Keys 2 to change the speed of the pump. The LED displays the value of the frequency. The actual speed (rpm) is about 5.8 times of frequency value. Direction: Press the [MODE/RESET] key continuously till the LED displays [Frd] when the [FWD] indicator which is in the left side of LED screen lights. Press the Speed Adjustment/ Data Input Keys 2, the LED displays [REV]. The [REV] indicator lights at the same time and the motor rotates reversely. When the [REV] indicator which is in the left side of the LED screen lights, switch to [FWD] mode in the same way. Display Convert: Press the [MODE/RESET] key continuously can show the following parameters alternatively: F: setting the frequency; H: the actual running frequency; A: the current of the motor. Frequency Converter Troubleshooting: Frequency converter has many warning and protective functions. The motor will stop automatically when the pump is in abnormal status. Eliminate the abnormal status and press the [MODE/RESET] key the pump can work continuously. The letters or the symbols on the LED display show the information of abnormal status. For details please see the <SE Series Frequency Converter Operating Manual > |
귀하의 성공적인 연구개발의 동반자가 되겠습니다.
***************************************************************************************
동방하이테크상사
http://www.allpump.co.kr
서울시 성동구 광나루로6길 35, 성수이비즈센터 710호
T)02-457-6292 F)457-6293 dbht@allpump.co.kr
***************************************************************************************
정량펌프, 정밀펌프, 고압펌프, 마이크로펌프, OEM 펌프, HPLC 펌프, 피스톤펌프, 주사기펌프, 실린지펌프, 다이어프램펌프, 다이아프램펌프, 튜브펌프, 튜빙펌프, 호스펌프, 연동펌프, 기어펌프, 기아펌프, 플런져펌프, 부란자펌프, 초정밀펌프, 초미세펌프, 초고압펌프, 밸브, 피팅, 튜빙, 아답터, 크로마토그래피 제품, 연구실험기자재 등