튜브연동펌프 부속품
[Peristaltic Pump Accessories]
Dispensing Controller
Foot Switch
External Control Module


카탈로그

2019-2020+English_peri-oem_dbht200527.vol1.egg
10.00MB
2019-2020+English_peri-oem_dbht200527.vol2.egg
10.00MB
2019-2020+English_peri-oem_dbht200527.vol3.egg
10.00MB
2019-2020+English_peri-oem_dbht200527.vol4.egg
0.12MB

 


주문정보

 

Dispensing Controller


Dispensing time 0-99.99S
Pause time 0-99.99S
Time resolution 0.01S
Work mode Single or multiple
Internal count range 0-999, count up or count down
External count range 999999,0 means unlimited cycle
External Start/Stop Open circuit
Memory function Repower the pump, user can choose whether to continue in accordance with the state before the power-down
Power supply AC 220V/5W
Type Product code Function
FK-1C 05.49.25A Dispensing controller can be equipped with many peristaltic pumps, gear pumps to realize dispensing automatically.
Foot Switch


Type Product code Connector Applicable Function
JK-1 05.49.20A DB-9 Peristaltic Pumps Gated: Pump stops when it is powered on. Pump runs when press down the footswitch; and pump stops when release the footswitch.
Trigger: Pump stops when it is powered on. Pump runs when footswitch is pressed once, and pump will stop when footswitch is pressed again.
JK-2 05.49.20B DB-9 Dispensing Controller Trigger: Pump stops when it is powered on. Pump runs when footswitch is pressed once, and pump will stop when footswitch is pressed again.
JK-3 05.49.20C DB-15 Peristaltic Pumps Gated: Pump stops when it is powered on. Pump runs when press down the footswitch; and pump stops when release the footswitch.
JK-4 05.49.20D DB-9 LSP Syringe Pumps Gated: Pump stops when it is powered on. Pump runs when press down the footswitch; and pump stops when release the footswitch.
Trigger: Pump stops when it is powered on. Pump runs when footswitch is pressed once, and pump will stop when footswitch is pressed again.
JK-5 05.49.20E DB-15 TJ Syringe Pumps Trigger: Pump stops when it is powered on. Pump runs when footswitch is pressed once (press down and release), and pump will stop when footswitch is pressed again.
JK-6 05.49.20F None TS Syringe Pumps Trigger: Pump stops when it is powered on. Pump runs when footswitch is pressed once (press down and release), and pump will stop when footswitch is pressed again.
JK-8 05.49.20H 9-pin YT600-1J
JK-9 05.49.20I 9-pin WT600-3J
JK-10 05.49.20J 9-pin WT600-4F
JK-11 05.49.20K DB-15 Peristaltic Pumps
JK-12 05.49.20L DB-9 Peristaltic Pumps
JK-13 05.49.20M None FK-100Z
JK-14 05.49.20N BNC LLP01-100
External Control Interface

Type Product code Connector
0~5 V 05.49.31A DB-15 BQ50-1J, WT3000-1JA, BT100-2J, BT100-1F, WT3000-1FA, BT300-2J, BT300-1F, WT3000-1JB, BT600-2J, WT600-2J, WT3000-1FB, WT600-1F
0~10 V 05.49.31B DB-15
4~20 mA 05.49.31C DB-15
0~10 kHz 05.49.31D DB-15
RS-485 05.49.31E DB-15
WK-01 - - Change (4-20mA, 0-5V, 0-10V) on the basis of standard analog external control module on the increase in internal and external control conversion.
Wk-02 - - Switching control start and stop supporting OEM100J-75
WK-03 - - Switching control start and stop supporting OEM100J-75
WK-04 - - Switching control peristaltic pump (except aeronautical product plug interfaces) start and stop, stop short, disconnected operation
WK-05 - - Switching control peristaltic pump WT600-3J, WT600-4F start and stop
WK-06 - - Switching control start and stop, fault alarm output by the extraction module
WK-07 - - WK-04 module controls the start and stop logic is inverted; short run, stop off
WK-08 - - External control only controls the start and stop buttons control the speed of the internal control, 5V stopped, suspended the operation according to the original state
WK-09 - - External control only controls the start and stop buttons control the speed of the internal control, 24V stopped, suspended the operation according to the original state
WK-10 - - External control switch start and stop and direction control, speed control button internal, supporting BT100-2J-12 & YZ1515X
WK-11 - - Increase external control switch function on the basis of external control 0-10V
WK-12 - - And supporting the use of BT100-2J-18, DB15 connected to drive external control interface, DB9 pin 2 Take 0-10V negative, positive needle 5 then 0-10V
WK-17 - - Adaptation LSP02-1B-1, by switching control and direction of the pump start and stop.
WK-18 - - Supporting BT100-2J-21
WK-19 - - Supporting the use TJ-3A-5, switch control, external control start and stop and direction control

 