외부제어인터페이스
[External Control Interface]
LONGER | |
4-20mA
0-5V/0-10V
0~10 kHz
RS-485
|
1.주문정보
Dispensing Controller
|
|||||
|
|||||
Dispensing time
|
0-99.99S
|
||||
Pause time
|
0-99.99S
|
||||
Time resolution
|
0.01S
|
||||
Work mode
|
Single or multiple
|
||||
Internal count range
|
0-999, count up or count down
|
||||
External count range
|
999999,0 means unlimited cycle
|
||||
External Start/Stop
|
Open circuit
|
||||
Memory function
|
Repower the pump, user can choose whether to continue in accordance with the state before the power-down
|
||||
Power supply
|
AC 220V/5W
|
||||
Type
|
Product code
|
Function
|
|||
FK-1C
|
05.49.25A
|
Dispensing controller can be equipped with many peristaltic pumps, gear pumps to realize dispensing automatically.
|
Foot Switch
|
||||
|
||||
Type
|
Product code
|
Connector
|
Applicable
|
Function
|
JK-1
|
05.49.20A
|
DB-9
|
Peristaltic Pumps
|
Gated: Pump stops when it is powered on. Pump runs when press down the footswitch; and pump stops when release the footswitch.
Trigger: Pump stops when it is powered on. Pump runs when footswitch is pressed once, and pump will stop when footswitch is pressed again.
|
JK-2
|
05.49.20B
|
DB-9
|
Dispensing Controller
|
Trigger: Pump stops when it is powered on. Pump runs when footswitch is pressed once, and pump will stop when footswitch is pressed again.
|
JK-3
|
05.49.20C
|
DB-15
|
Peristaltic Pumps
|
Gated: Pump stops when it is powered on. Pump runs when press down the footswitch; and pump stops when release the footswitch.
|
JK-4
|
05.49.20D
|
DB-9
|
LSP Syringe Pumps
|
Gated: Pump stops when it is powered on. Pump runs when press down the footswitch; and pump stops when release the footswitch.
Trigger: Pump stops when it is powered on. Pump runs when footswitch is pressed once, and pump will stop when footswitch is pressed again.
|
JK-5
|
05.49.20E
|
DB-15
|
TJ Syringe Pumps
|
Trigger: Pump stops when it is powered on. Pump runs when footswitch is pressed once (press down and release), and pump will stop when footswitch is pressed again.
|
JK-6
|
05.49.20F
|
None
|
TS Syringe Pumps
|
Trigger: Pump stops when it is powered on. Pump runs when footswitch is pressed once (press down and release), and pump will stop when footswitch is pressed again.
|
JK-8
|
05.49.20H
|
9-pin
|
YT600-1J
|
|
JK-9
|
05.49.20I
|
9-pin
|
WT600-3J
|
|
JK-10
|
05.49.20J
|
9-pin
|
WT600-4F
|
|
JK-11
|
05.49.20K
|
DB-15
|
Peristaltic Pumps
|
|
JK-12
|
05.49.20L
|
DB-9
|
Peristaltic Pumps
|
|
JK-13
|
05.49.20M
|
None
|
FK-100Z
|
|
JK-14
|
05.49.20N
|
BNC
|
LLP01-100
|
|
External Control Interface
|
|||
|
|||
Type
|
Product code
|
Connector
|
|
0~5 V
|
05.49.31A
|
DB-15
|
BQ50-1J, WT3000-1JA, BT100-2J, BT100-1F, WT3000-1FA, BT300-2J, BT300-1F, WT3000-1JB, BT600-2J, WT600-2J, WT3000-1FB, WT600-1F
|
0~10 V
|
05.49.31B
|
DB-15
|
|
4~20 mA
|
05.49.31C
|
DB-15
|
|
0~10 kHz
|
05.49.31D
|
DB-15
|
|
RS-485
|
05.49.31E
|
DB-15
|
|
WK-01
|
-
|
-
|
Change (4-20mA, 0-5V, 0-10V) on the basis of standard analog external control module on the increase in internal and external control conversion.
|
Wk-02
|
-
|
-
|
Switching control start and stop supporting OEM100J-75
|
WK-03
|
-
|
-
|
Switching control start and stop supporting OEM100J-75
|
WK-04
|
-
|
-
|
Switching control peristaltic pump (except aeronautical product plug interfaces) start and stop, stop short, disconnected operation
|
WK-05
|
-
|
-
|
Switching control peristaltic pump WT600-3J, WT600-4F start and stop
|
WK-06
|
-
|
-
|
Switching control start and stop, fault alarm output by the extraction module
|
WK-07
|
-
|
-
|
WK-04 module controls the start and stop logic is inverted; short run, stop off
|
WK-08
|
-
|
-
|
External control only controls the start and stop buttons control the speed of the internal control, 5V stopped, suspended the operation according to the original state
|
WK-09
|
-
|
-
|
External control only controls the start and stop buttons control the speed of the internal control, 24V stopped, suspended the operation according to the original state
|
WK-10
|
-
|
-
|
External control switch start and stop and direction control, speed control button internal, supporting BT100-2J-12 & YZ1515X
|
WK-11
|
-
|
-
|
Increase external control switch function on the basis of external control 0-10V
|
WK-12
|
-
|
-
|
And supporting the use of BT100-2J-18, DB15 connected to drive external control interface, DB9 pin 2 Take 0-10V negative, positive needle 5 then 0-10V
|
WK-17
|
-
|
-
|
Adaptation LSP02-1B-1, by switching control and direction of the pump start and stop.
|
WK-18
|
-
|
-
|
Supporting BT100-2J-21
|
WK-19
|
-
|
-
|
Supporting the use TJ-3A-5, switch control, external control start and stop and direction control
|
2.관련제품
|
|
|
연동펌프 튜빙, 핏팅
[Peristaltic Pump Tubing & Fitting]
|
FK-1C 디스펜서 콘트롤러
FK-1C Dispensing Controller
|
튜브연동펌프 부속품
[Peristaltic Pump Accessories]
|
Silicon Peristaltic Pump Tubing
PharMed BPT Peristaltic Pump Tubing
Norprene Chemical Peristaltic Pump Tubing
Tygon R-3603 Peristaltic Pump Tubing
Tygon F-4040 Peristaltic Pump Tubing
Viton Peristaltic Pump Tubing
Fluran F-5500 Peristaltic Pump Tubing
Peristaltic Pump Tubing
Peristaltic Pump Fitting
|
Dispensing time : 0-99.99S
Pause time :0-99.99S
Time resolution : 0.01S
Work mode : Single or multiple
|
Dispensing Controller
Foot Switch
External Control Module
|
정량펌프, 정밀펌프, 고압펌프, 마이크로펌프, OEM 펌프, HPLC 펌프, 피스톤펌프, 주사기펌프, 실린지펌프, 다이어프램펌프, 다이아프램펌프, 튜브펌프, 튜빙펌프, 호스펌프, 연동펌프, 기어펌프, 기아펌프, 플런져펌프, 부란자펌프, 초정밀펌프, 초미세펌프, 초고압펌프, 밸브, 피팅, 튜빙, 아답터, 크로마토그래피 제품, 연구실험기자재 등