본문 바로가기

카테고리 없음

[LONGER] - 외부제어인터페이스

외부제어인터페이스
[External Control Interface]
LONGER
4-20mA
0-5V/0-10V
0~10 kHz
RS-485
 

1.주문정보

Dispensing Controller
Dispensing time
0-99.99S
Pause time
0-99.99S
Time resolution
0.01S
Work mode
Single or multiple
Internal count range
0-999, count up or count down
External count range
999999,0 means unlimited cycle
External Start/Stop
Open circuit
Memory function
Repower the pump, user can choose whether to continue in accordance with the state before the power-down
Power supply
AC 220V/5W
Type
Product code
Function
FK-1C
05.49.25A
Dispensing controller can be equipped with many peristaltic pumps, gear pumps to realize dispensing automatically.
Foot Switch
Type
Product code
Connector
Applicable
Function
JK-1
05.49.20A
DB-9
Peristaltic Pumps
Gated: Pump stops when it is powered on. Pump runs when press down the footswitch; and pump stops when release the footswitch.
Trigger: Pump stops when it is powered on. Pump runs when footswitch is pressed once, and pump will stop when footswitch is pressed again.
JK-2
05.49.20B
DB-9
Dispensing Controller
Trigger: Pump stops when it is powered on. Pump runs when footswitch is pressed once, and pump will stop when footswitch is pressed again.
JK-3
05.49.20C
DB-15
Peristaltic Pumps
Gated: Pump stops when it is powered on. Pump runs when press down the footswitch; and pump stops when release the footswitch.
JK-4
05.49.20D
DB-9
LSP Syringe Pumps
Gated: Pump stops when it is powered on. Pump runs when press down the footswitch; and pump stops when release the footswitch.
Trigger: Pump stops when it is powered on. Pump runs when footswitch is pressed once, and pump will stop when footswitch is pressed again.
JK-5
05.49.20E
DB-15
TJ Syringe Pumps
Trigger: Pump stops when it is powered on. Pump runs when footswitch is pressed once (press down and release), and pump will stop when footswitch is pressed again.
JK-6
05.49.20F
None
TS Syringe Pumps
Trigger: Pump stops when it is powered on. Pump runs when footswitch is pressed once (press down and release), and pump will stop when footswitch is pressed again.
JK-8
05.49.20H
9-pin
YT600-1J
JK-9
05.49.20I
9-pin
WT600-3J
JK-10
05.49.20J
9-pin
WT600-4F
JK-11
05.49.20K
DB-15
Peristaltic Pumps
JK-12
05.49.20L
DB-9
Peristaltic Pumps
JK-13
05.49.20M
None
FK-100Z
JK-14
05.49.20N
BNC
LLP01-100
External Control Interface
Type
Product code
Connector
0~5 V
05.49.31A
DB-15
BQ50-1J, WT3000-1JA, BT100-2J, BT100-1F, WT3000-1FA, BT300-2J, BT300-1F, WT3000-1JB, BT600-2J, WT600-2J, WT3000-1FB, WT600-1F
0~10 V
05.49.31B
DB-15
4~20 mA
05.49.31C
DB-15
0~10 kHz
05.49.31D
DB-15
RS-485
05.49.31E
DB-15
WK-01
-
-
Change (4-20mA, 0-5V, 0-10V) on the basis of standard analog external control module on the increase in internal and external control conversion.
Wk-02
-
-
Switching control start and stop supporting OEM100J-75
WK-03
-
-
Switching control start and stop supporting OEM100J-75
WK-04
-
-
Switching control peristaltic pump (except aeronautical product plug interfaces) start and stop, stop short, disconnected operation
WK-05
-
-
Switching control peristaltic pump WT600-3J, WT600-4F start and stop
WK-06
-
-
Switching control start and stop, fault alarm output by the extraction module
WK-07
-
-
WK-04 module controls the start and stop logic is inverted; short run, stop off
WK-08
-
-
External control only controls the start and stop buttons control the speed of the internal control, 5V stopped, suspended the operation according to the original state
WK-09
-
-
External control only controls the start and stop buttons control the speed of the internal control, 24V stopped, suspended the operation according to the original state
WK-10
-
-
External control switch start and stop and direction control, speed control button internal, supporting BT100-2J-12 & YZ1515X
WK-11
-
-
Increase external control switch function on the basis of external control 0-10V
WK-12
-
-
And supporting the use of BT100-2J-18, DB15 connected to drive external control interface, DB9 pin 2 Take 0-10V negative, positive needle 5 then 0-10V
WK-17
-
-
Adaptation LSP02-1B-1, by switching control and direction of the pump start and stop.
WK-18
-
-
Supporting BT100-2J-21
WK-19
-
-
Supporting the use TJ-3A-5, switch control, external control start and stop and direction control

2.관련제품


연동펌프 튜빙, 핏팅
[Peristaltic Pump Tubing & Fitting]
FK-1C 디스펜서 콘트롤러
FK-1C Dispensing Controller
튜브연동펌프 부속품
[Peristaltic Pump Accessories]
Silicon Peristaltic Pump Tubing
PharMed BPT Peristaltic Pump Tubing
Norprene Chemical Peristaltic Pump Tubing
Tygon R-3603 Peristaltic Pump Tubing
Tygon F-4040 Peristaltic Pump Tubing
Viton Peristaltic Pump Tubing
Fluran F-5500 Peristaltic Pump Tubing
Peristaltic Pump Tubing
Peristaltic Pump Fitting
Dispensing time : 0-99.99S
Pause time :0-99.99S
Time resolution : 0.01S
Work mode : Single or multiple
Dispensing Controller
Foot Switch
External Control Module

정량펌프, 정밀펌프, 고압펌프, 마이크로펌프, OEM 펌프, HPLC 펌프, 피스톤펌프, 주사기펌프, 실린지펌프, 다이어프램펌프, 다이아프램펌프, 튜브펌프, 튜빙펌프, 호스펌프, 연동펌프, 기어펌프, 기아펌프, 플런져펌프, 부란자펌프, 초정밀펌프, 초미세펌프, 초고압펌프, 밸브, 피팅, 튜빙, 아답터, 크로마토그래피 제품, 연구실험기자재 등