특징 및 규격 | Hamilton은 산업 전반에 걸쳐 사용되는 다양한 종류의 표준주사기와 주문제작주사기를 공급하고 있습니다. 다양한 구조로 된 0.5 μL ~ 2 L 범위의 용량을 가진 주사기 최고 수준의 정밀도와 정확도를 제공합니다. 800 여종의 주사기는 주사기형태와 용량, 터미널 구조, 주사기니들의 굵기, 길이 , 형태에 따라 800 여종의 주사기가 있습니다. | Syringe Terminations; Terminations are located at the end of the syringe barrel and function as the interface between the syringe and its mating connection such as the needle. Terminations are offered in a number of different needle and connection configurations to accommodate a broad range of applications. N, Cemented Needle
| SN, Special Cemented Needle
| LTN, Luer Tip Cemented Needle
| LTSN, Luer Tip Cemented Needle Special
| LT, Luer Tip
| RN, Removable Needle
| KH, Knurled Hub
| FN, Fixed Needle
| TLL, Teflon Luer Lock
| BFP, Bubble Free Prime
| SL, SampleLock™
| C, ChemSeal
| CA, Carbon Analyzer
| DX, Diluter with Stop
| DAD, Diluter AccuDil
| AD, AccuDil
| Tracheal
| |
| Point Style; Several different needle point styles are offered on Hamilton syringe and needle products depending on the application. The correct point style varies depending on the intended application. Below are a few examples of common applications. Point Style 2 | Point Style 3 | Point Style 3T | Point Style 4 | Point Style 5 | Point Style AS |
| Gauge Index ; When selecting a needle gauge it is important to keep in mind the volume of the syringe and the dead volume of the needle. For example, it will be very difficult to prime a 10 µL syringe if the dead volume in the needle is greater than 10 µL. Refer to the gauge index to choose a needle gauge with an appropriate µL/inch before selecting a needle. Select the minimum length that allows you to carry out your application comfortably. Gauge | Nominal OD(mm) | Nominal ID(mm) | Wal Thickness(mm) | Volume(uL/inch) | 34 | 0.159 | 0.051 | 0.051 | 0.052 | 33 | 0.210 | 0.108 | 0.051 | 0.233 | 32 | 0.235 | 0.108 | 0.064 | 0.233 | 31 | 0.261 | 0.133 | 0.064 | 0.353 | 30 | 0.312 | 0.159 | 0.076 | 0.504 | 29 | 0.337 | 0.184 | 0.076 | 0.675 | 28 | 0.362 | 0.184 | 0.089 | 0.675 | 27 | 0.413 | 0.210 | 0.102 | 0.876 | 26s | 0.474 | 0.127 | 0.178 | 0.322 | 26 | 0.464 | 0.260 | 0.102 | 1.349 | 25s | 0.515 | 0.153 | 0.178 | 0.464 | 25 | 0.515 | 0.260 | 0.127 | 1.349 | 24 | 0.566 | 0.311 | 0.127 | 1.930 | 23s | 0.642 | 0.116 | 0.267 | 0.268 | 23 | 0.642 | 0.337 | 0.152 | 2.266 | 22s | 0.718 | 0.168 | 0.279 | 0.563 | 22 | 0.718 | 0.413 | 0.152 | 3.403 | 21 | 0.819 | 0.514 | 0.152 | 5.271 | 20 | 0.908 | 0.603 | 0.152 | 7.255 | 19 | 1.067 | 0.686 | 0.191 | 9.389 | 18 | 1.270 | 0.838 | 0.216 | 14.011 | 17 | 1.473 | 1.067 | 0.203 | 22.715 | 16 | 1.651 | 1.194 | 0.229 | 28.444 | 15 | 1.829 | 1.372 | 0.229 | 37.529 | 14 | 2.109 | 1.600 | 0.254 | 51.076 | 13 | 2.413 | 1.804 | 0.305 | 64.895 | 12 | 2.769 | 2.159 | 0.305 | 93.000 | 11 | 3.048 | 2.388 | 0.330 | 113.728 | 10 | 3.404 | 2.693 | 0.356 | 144.641 |
|
|
주문정보 | Microliter Syringes; Microliter syringes are for use with liquids only. They incorporate a hand-fitted stainless steel plunger with a finely bored syringe barrel. These syringes are ideal for homogeneous samples that are not prone to precipitation or bonding with glass. Under the proper conditions, plunger wear is minimal and the life of a Microliter syringe is almost unlimited. However, when using heterogeneous solutions with a Microliter syringe, the user must be especially diligent about cleaning the syringe after each use. For more information, see our Hamilton Syringe Care and Use Guide on properly maintaining our syringes. In some cases, even diligent cleaning is not sufficient and the barrel will become soiled. The deposits on the glass will compromise the tight tolerances between the glass and the plunger resulting in a frozen plunger. Plungers for Microliter syringes cannot be interchanged or replaced if damaged. For heterogeneous solutions, a Gastight syringe is the best option. | Gastight Syringes; Gastight syringes are ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze. | Calibrated Syringes; Hamilton Company offers a calibration service for precision syringes and Digital Syringes. A Certificate of Calibration is provided with the product and the procedure is performed with an unbroken chain of calibrations traceable to N.I.S.T. Calibrated precision syringes are available only at the time of purchase. To order a calibrated syringe, add the prefix "CAL" to the beginning of the syringe's part number. For example, to order a calibrated 701N, 10 μL syringe (part number 80300), request part number CAL80300. | Digital Syringes ; Reading graduations is always a challenge. The Hamilton Digital Syringe eliminates parallax errors by providing a digital readout on its integrated LCD screen. An adjustable plunger-stop guarantees reproducible plunger placement. Easily achieve precision up to 0.5% while dispensing volumes from 500 µL down to 50 nL. | Carbon Analyzer Syringes; These syringes are for water analysis with Total Organic Carbon (TOC) analyzers. The wetted parts are stainless steel and borosilicate glass. The plungers and barrels are not interchangeable or replaceable. | Chromatography & Analytic Syringes; Hamilton Company manufactures a complete range of syringes for partial loop filling, complete loop filling and reverse loop filling by the aspiration HPLC technique. Syringes for a complete range of GC applications, including: capillary and packed column methods, on-column and split/splitless injection techniques, use of Merlin Microseal™ and JADE injectors and headspace sampling protocols. Find the ideal syringe for High Performance Liquid Chromatography (HPLC), Gas Chromatography (GC) or Thin Layer Chromatography (TLC) by selecting the applicable sub category or see a list of all chromatography syringes by selecting the filtering tool. | Instrument Syringes; For over 50 years Hamilton has been the trusted partner for robotic and clinical diagnostic instrumentation. Our syringes provide the accuracy and precision that enables many of the automated processes around the laboratory. In addition to syringes for Hamilton equipment we offer a wide variety of syringes for other automated systems. | Life Science Syringes; Hamilton Company offers a wide variety of specialized syringes for life science applications. From custom needles to specialized animal injections and gel loading syringes Hamilton has a solution for your precision liquid handling application. | Needles; Hamilton Company offers the widest variety of standard and custom needles in the industry. Manufactured from 304 stainless steel and with needle gauges from 10 to 34 and lengths from 0.375 to 12+ inches almost any needle is possible. | Syringe Accessories; Hamilton manufactures a variety of syringe accessories to improve or modify the functionality of a standard syringe. There are solutions that prevent plunger bending and increase reproducibility to cleaning tools that prolong the life of a syringe. |
|
귀하의 성공적인 연구개발의 동반자가 되겠습니다. ******************************************************************************************************************* 동방하이테크상사 http://www.allpump.co.kr 서울시 광진구 광장동 127 리버힐오피스텔 309호 T)02-457-6292 F)457-6293 dbht@allpump.co.kr *******************************************************************************************************************
정량펌프, 정밀펌프, 고압펌프, 마이크로펌프, OEM 펌프, HPLC 펌프, 피스톤펌프, 주사기펌프, 실린지펌프, 다이어프램펌프, 다이아프램펌프, 튜브펌프, 튜빙펌프, 호스펌프, 연동펌프, 기어펌프, 기아펌프, 플런져펌프, 부란자펌프, 초정밀펌프, 초미세펌프, 초고압펌프, 밸브, 피팅, 튜빙, 아답터, 크로마토그래피 제품, 연구실험기자재 등
|