특 징 |
| |
규 격 |
+ 확대한 그림보기 -> |
TJ-3A/W0109-1B |
TS-1B/W0109-1B |
TJP-3A/W0109-1B |
Working Mode |
Infusion/Withdrawal |
Programmable |
Channel |
1 |
1~4 |
1 |
Syringe |
5 uL ~ 1.0 mL |
Stroke |
90 mm |
Pusher Advance |
0.165 um/step |
Linear Speed |
7.94 um/min ~ 79.4 mm/min |
Linear Resolution |
7.94 um/min |
Linear Accuracy |
≤±0.5% when ≥30% of pump stroke |
Linear Force |
≥9 kg (20 lbs) |
Syringe Selection |
Built-in syringe branched, size and inner diameters |
Syringe Defined |
Can store four user-defined syringe inner diamerters |
Flowrate Calibration |
Improve flowrate accuracy |
Running Parameter |
Dispensin volume can be each channel, all channel use the parameters of the specified channel |
Start setting |
Each drive unit can be started seperately, simultanously or according to each delay time |
Display Setting |
Display volume, flowrate or linear speed |
Power-off Memory |
Select keeping previous state or resetting parameters when power on |
Forwarard/backward |
Infuse or withrawal liquid at full speed |
State Output |
2 OC gate signal to indicate start/stop and direction |
Control Input |
3 TTL signal to control start/stop, fast forwarard and fast backward |
Communication |
RS-485 |
Drive unit dimension |
180 L x 46W x 78 mmH |
Drive unit weight |
0.6 kg |
Controller dimension |
170Lx108Wx65mmH |
235Lx178Wx74mmH |
170Lx108Wx65mmH |
Controller weight |
0.5 kg |
0.8 kg |
0.5 kg |
Power |
AC 90-260V/10W |
AC 90-260V/40W |
AC 90-260V/10W | |
Syringe |
Diameter (mm) |
Flowrate (uL/min~mL/min) |
1 mL |
4.72 |
0.139-1.39 |
2 mL |
9.00 |
0.505-5.05 |
5 mL |
13.10 |
1.07-10.7 |
10 mL |
16.60 |
1.718-17.18 |
20 mL |
19.00 |
2.251-22.51 |
30 mL |
23.00 |
3.298-32.98 |
60 mL |
29.14 |
5.295-52.95 | | |
기술자료 |
Programmable Syringe Pump TJP-3A Flow Rates Calibration (Release Time:2017-01-20)
Flow calibration: Operator can get more accurate flow through calibratingthe diameter of syringe barrel.
In work interface and stop state, press RCS to enter menu setting interface,turn RCS to highlight “Calibration”, press RCS to enter next interface, the first line display the programmed flow in current mode; the second line displays the testing time whose range is from 1 to 60 minutes. The third line displays theoretical volume (the product of flow and testing time) or input measured volume directly. The fourth line displays the start/stop and direction state.
Calibration procedure: set testing time first, start pump. Pump automatically stop after the testing time is over, measure the liquid volume and input the measured volume, the calibration is over. If knew the measured volume in advance, operator can directly input the measured volume.
|
Programmable Syringe Pump TJP-3A External Control (Release Time:2017-01-20)
Control the Start/Stop of the pump by external signal, the trigger and gate modes are optional.
In work interface and stop state, press RCS to enter menu setting interface turn RCS to highlight “EXT control”, press RCS to enter external start/stop mode setting interface. Press RCS again to select “Trigger” or “Gate”, press RCS to save the setting. | |
| |
귀하의 성공적인 연구개발의 동반자가 되겠습니다.
******************************************************************************************************************* 동방하이테크상사 http://www.allpump.co.kr 서울시 광진구 광장동 127 리버힐오피스텔 309호 T)02-457-6292 F)457-6293 dbht@allpump.co.kr ******************************************************************************************************************* 정량펌프, 정밀펌프, 고압펌프, 마이크로펌프, OEM 펌프, HPLC 펌프, 피스톤펌프, 주사기펌프, 실린지펌프, 다이어프램펌프, 다이아프램펌프, 튜브펌프, 튜빙펌프, 호스펌프, 연동펌프, 기어펌프, 기아펌프, 플런져펌프, 부란자펌프, 초정밀펌프, 초미세펌프, 초고압펌프, 밸브, 피팅, 튜빙, 아답터, 크로마토그래피 제품, 연구실험기자재 등
|