펄스댐퍼 (Pulse Damper) |
The ASI
FlatLine™ Pulse Damper combines performance and
reliability in a simple, easy to use housing. Standard 10-32 inlet and outlet
ports allow quick connection into virtually any HPLC system. Solid core
technology provides reliable long term operation without the down time
associated with ruptured or leaking membrane dampers. Custom sizes and
additional features like integral prime/purge valve available for the OEM
market.
Although similar to the standard ASI FlatLine™ Damper, the HC (High Capacity)
features a bimodal damping mechanism which includes solid core and dynamic
spring deflection. This combination increases damping efficiency over a wider
pressure range. The HC is particularly well suited for damping at low pressures,
below 500 PSI. |
| |
특 징 |
Rupture
proof Pulse Damper with no diaphragm |
Flow path
geometry combines clean flush out with minimal internal
volume |
Custom sizes
available for OEM |
FlatLine™ HC (High Capacity)
increases damping efficiency and range |
Can be
manufactured to include a pressure transducer and/or a prime purge
valve | |
주문정보 |
ASI Part Number |
ASI FlatLine™ Pulse
Damper |
590-0001 |
ASI FlatLine™ HC Pulse
Damper |
590-0010 | | |
|
체크밸브 (In-line Check
Valve) |
The ASI in-line check valve incorporates many of the innovations of our
self-priming replacement check valves. It is a rapid closure cartridge valve
that features very low resistance to flow, low internal volume, and operates
independently of gravity. It is protected from solvent contamination by a 1/4"
diameter 2 micron frit, and features crush-proof construction. The valve may be
used whenever fluid flow needs to be restricted to one direction. Applications
include prevention of post column derivitization fluids from back-flowing into
the column in the event of mobile phase pump failure. This valve is also
available in a high temperature version that will operate at up to 125º C and
5000 PSI. (Please call for more information). |
| |
규 격 |
Internal Volume |
Cracking Pressure |
Maximum Pressure |
Cv* |
250-2000
In-Line CV Assembly |
48 µL |
1.0 PSI |
15,000 PSI |
0.005 |
250-2006
In-Line CV Cartridge |
250-2000UHP
In-line CV Assembly |
48 µL |
1.0 PSI |
30,000 PSI |
0.005 |
250-2000UHP
In-line CV Cartage |
250-2001
In-line CV Assembly |
60 µL |
1.0 PSI |
15,000 PSI |
0.02 |
250-2001
In-line CV Cartage |
*Cv of 1.0 is
defined as one gallon per minute of 60 °F water resulting from a 1 PSI pressure
drop. 1 gallon = 3,785 mL. |
주문정보 |
ASI Part Number |
In-Line
Check Valve with 1/8" Ball Cartridge |
250-2000 |
Replacement
1/8" Ball Cartridge |
250-2006 |
In-Line
Check Valve with 1/8" Ball Cartridge Ultra High Pressure |
250-2000UHP |
Replacement
1/8" Ball Cartridge Ultra High Pressure |
250-2006UHP |
In-Line
Check Valve with 3/16" Ball Cartridge |
250-2001 |
Replacement
3/16" Ball Cartridge |
250-2007 | | |
|
핏팅, 유니온 (Fittings and
Unions) |
Universal fittings and unions are compatible with most HPLC
fittings such as Parker, Swagelok, Valco, Upchurch, Beckman, and Waters, when
initially assembled with new ferrules. All components are manufactured from 316
stainless steel, and are cleaned and passivated. Unions come complete with 1/16"
compression fittings. |
| |
주문정보 |
ASI Part Number |
ZDV Straight
Union 0.040” Thru |
920-0624 |
ZDV Straight
Union 0.020” Thru |
920-0622 |
10-32
Compression Screw 1/16” Tube 10/Pack |
900-0622 |
10-32
Compression Screw 1/16” Tube 25/Pack |
900-0623 |
Ferrule for
1/16" Tube 10/Pack |
910-0622 |
Ferrule for
1/16" Tube 25/Pack |
910-0623 |
PEEK
Fingertight Fittings for 1/16” TFE, PEEK Tube |
800-0630 |
PEEK
Fingertight Fittings for 1/16” TFE, PEEK Tube 10/Pack |
800-0631 | |
| |
|
필터
(Filter) |
Solvent Filters |
|
It is essential to use a solvent filter
at the pump intake to insure reliable operation of the check valves and other
pump system components. We recommend a 10 micron filter for most analytical
applications. For flow rates in excess of 10 mL per minute, we recommend a 20
micron filter to avoid pump cavitation. ASI filters are designed to slip inside either
1/16" ID or 1/8" ID tubing, and are made from 316 stainless
steel. |
주문정보 |
ASI Part Number |
10 micro
Solvent Filter for 1/16" ID |
850-0620 |
10 micro
Solvent Filter for 1/16" ID 5/Pack |
850-0621 |
10 micro
Solvent Filter for 1/8" ID |
850-1250 |
10 micro
Solvent Filter for 1/8" ID 5/Pack |
850-1251 |
20 micro
Solvent Filter for 1/8" OD |
850-1248 |
20 micro
Solvent Filter for 1/8" OD 5/Pack |
850-1249 | |
ColumnShield Precolumn Filter |
|
PrimeLine ColumnShield precolumn filter provides economical
protection from the harmful effects of sample and mobile phase particulates on
modern HPLC columns. The disposable filter was engineered to maintain the
efficiency of high performance columns assuring insuring no loss of critical
resolution. With its simple design, the filter installs in any analytical column
or guard column in seconds and is leak tight to 5,000 PSI. To install simply
hand tighten the filter as you would with any fingertight fitting while holding
the column stable. |
특 징 |
Economical
protection against micro-particles |
Extends HPLC
column lifetime |
Negligible
effect on column performance |
Universal
fit, connects directly to column |
Fingertight
to 5,000 PSI |
규 격 |
Inlet/Outlet |
: Female/Male 10-32 |
Port
Geometry |
: Parker (1/16 CPI) |
Material |
: PEEK |
Filter |
: 0.5 micron Titanium |
Pressure
Rating |
: 5,000 psig |
Fingertight |
: No wrenches
required |
주문정보 |
ASI Part Number |
ColumnShield
Precolumn Filter, 0.5 micron |
850-1050 |
ColumnShield
Precolumn Filter, 0.5 micron, 5/Pack |
850-1050-05 |
ColumnShield
Precolumn Filter, 0.5 micron, 10/Pack |
850-1050-10 | |
In-Line HPLC/UHPLC
Filters |
Placed between the pump and injector, these filters protect the
injector from pump seal wear material and extend the life of the column
prefilter. All filters are made from 316 stainless steel and are rated to 6,000
PSI. Filters for UPLC are rated to 15,000 PSI. All male/female ports are
compatible with 10-32 compression fittings. |
|
|
High Capacity In-Line Filters |
Low Volume In-Line
Filters | |
High Capacity In-Line
Filters |
This filter features a clean-swept internal volume and a large
2.2 cm2 filter area that will provide a long service life. Filter cartridges are
available in 0.5 micron and 2 micron porosity,and are both interchangeable and
replaceable. Total internal volume is 100 μL for 0.5 micron filter, and 120 μL
for 2 micron filter. |
주문정보 |
ASI Part Number |
High
Capacity In-Line Filter Assembly, 2 micron |
850-1310 |
High
Capacity In-Line Filter Assembly, 2 micron, HP |
850-1310HP |
ColumnShield
Precolumn Filter, 0.5 micron, 10/Pack |
850-1050-10 |
High
Capacity In-Line Filter Assembly, 0.5 micron |
850-1315 |
High
Capacity In-Line Filter Assembly, 0.5 micron, HP |
850-1315HP |
2 micron
Replacement Filter Cartridge for HC |
850-1320 |
0.5 micron
Replacement Filter Cartridge for HC |
850-1325 | |
Low Volume In-Line
Filters |
Recommended for applications where system volume must be kept to
a minimum. Full use of the filter surface is maintained by a 5° entrance cone.
The 0.25” diameter replacement filter cartridges are available in 0.5 micron and
2 micron porosity, and have a 0.32 cm2 active area. Total internal volume is 14
μL for the 0.5 micron filter and 18 μL for the 2 micron filter. The 0.062”
replacement filter is 0.5 micron with 2 μL internal volume. |
주문정보 |
ASI Part Number |
High
Capacity In-Line Filter Assembly, 2 micron |
850-1310 |
High
Capacity In-Line Filter Assembly, 2 micron, High Pressure |
850-1310HP |
ColumnShield
Precolumn Filter, 0.5 micron, 10/Pack |
850-1050-10 |
High
Capacity In-Line Filter Assembly, 0.5 micron |
850-1315 |
High
Capacity In-Line Filter Assembly, 0.5 micron, High Pressure |
850-1315HP |
2 micron
Replacement Filter Cartridge for HC |
850-1320 |
0.5 micron
Replacement Filter Cartridge for HC |
850-1325 | | |
In-Line & Direct Connect HPLC/UHPLC Column
Filters |
PrimeLine direct connect precolumn filters provide economical
protection from the harmful effects of sample and mobile phase particulates on
modern HPLC and UHPLC columns. The PrimeLine precolumn filter was engineered
specifically for use in high throughput and routine HPLC separations where
mobile phase and sample contamination cause a decrease in column performance or
premature column failure. The low swept volume of the PrimeLine filter maintains
the efficiency of high performance columns assuring a negligible loss of
critical resolution. With its simple design, the PrimeLine filter installs in
any analytical column in seconds and is leak tight to 15,000 PSI. Simply finger
tighten initially, then wrench tighten an additional 1/4 - 1/2
turn. |
|
|
In-line Filter |
Direct Connect Column
Filter | |
특 징 |
Cost
effective way to extend column lifetime |
Replaceable
filter element |
Negligible
effect on column performance |
Universal
fit, connects directly to column |
Leak tight
to 15,000 PSI |
주문정보 |
ASI Part Number |
In-Line
Filter Assembly, 0.5 micron |
850-1025 |
Direct
Connect Column Filter Assembly, 0.5 micron |
850-1020 |
0.5 micron
.125" dia. x .062" Replacement Filter Assembly, 5/Pack |
850-1020-01 | |
UltraShield HPLC/UHPLC Precolumn
Filter |
|
UltraShield direct connect precolumn
filters provide economical protection from the harmful effects of sample and
mobile phase particulates on modern UHPLC and other high resolution HPLC
columns. UltraShield was engineered specifically for use in fast, high efficiency separations
requiring high mobile phase velocities and ultra high pressure. UltraShield maintains the
efficiency of these high performance columns assuring no loss of critical
resolution. With its simple design, UltraShield installs in any analytical column
in seconds and is leak tight to 15,000 PSI. Simply tighten the filter with a
wrench until it is snug, followed by an additional 1/4
turn. |
규 격 |
Inlet/Outlet |
: Female/Male 10-32 |
Port
Geometry |
: Parker (1/16 CPI) |
Material |
: Stainless Steel, PEEK ferrule |
Filter |
: 0.5 micron Titanium |
Pressure
Rating |
: 15,000 psig |
Wrench
Flat |
: 5/16” |
주문정보 |
ASI Part Number |
UltraShield
Precolumn Filter Assembly |
850-1010 |
UltraShield
Precolumn Filter Assembly, 5/Pack |
850-1010-05 |
UltraShield
Precolumn Filter Assembly, 10/Pack |
850-1010-10 | |
Guard Column HPLC/UHPLC Hardware |
|
The PrimeLine direct connect guard column provides
economical protection from the harmful effects of sample and mobile phase
particulates and soluble contaminants on modern HPLC and UHPLC columns. The low
swept volume of the PrimeLine guard column maintains the
efficiency of high performance columns assuring a negligible loss of critical
resolution. With its simple design, the PrimeLine guard column installs in any
analytical column in seconds and is leak tight to 10,000 PSI.
|
주문정보 |
ASI Part Number |
Guard Column
Housing |
850-1390 |
Guard Column
Assembly, 2 mm x 10 mm |
850-1392 |
Guard Column
Assembly, 4 mm x 10 mm |
850-1394 | | |
|
시료주입기 (Injectio
Valve) |
WX-100 Manual Injection Valve |
|
The WX-1000 manual injection valve is a traditional 6
port two position flat face shear valve with a front loading needle port,
designed for use in traditional HPLC chromatography
systems. |
특 징 |
Compatible
with Rheodyne 7725i spare parts |
Pmax 5,000
PSI adjustable to 7,000, Temperature 80°C |
Uninterruptable (non-pulsing) flow during
switching |
Self
adjusting stator seal for easy maintenance |
Improved
ceramic stator seal to eliminate wear and carry
over |
주문정보 |
ASI Part Number |
Manual
Injection Vavle,WX-1000-01 Kit, includes 20 µL loop |
A500-1017 |
Valve
rebuild Kit,WRX-1000 |
500-1017-RKIT |
VS Rotor
Seal |
500-1017-RS |
WX-1000
Stator, SS |
500-1017-STS |
Stator Face
Assembly |
500-1017-STF |
5 µl SS
Sample loop, 30° |
500-1017-05 |
10 µl SS
Sample loop, 30° |
500-1017-10 |
20 µl SS
Sample loop, 30° |
500-1017-20 |
100 µl SS
Sample loop, 30° |
500-1017-100 | | |
|
고압 정량밸브 (High Pressure
Metering Values) |
The High Pressure Adjustable Metering Valve maintains
a back pressure which is directly proportional to the inlet flow rate and
solvent viscosity. The valve has an adjustment range from 10 PSI to 5,000 PSI at
1.00 mL/min. with water. The dead volume is less than 4 µL with flow paths
designed to minimize dispersion. |
|
주문정보 |
ASI Part Number |
High
Pressure Metering Valve |
690-0000 | | |
|
튜빙(Tubing) |
1/16 " OD Stainless Steel Capillary |
|
ASI Capillary tubing is made from 316 stainless steel and is available in 25
ft. lengths; other lengths upon request. The tubing ID should be passivated
after cutting as follows: 20 % nitric acid for 30 minutes, followed by distilled
water rinse. |
Teflon (TFE) Tubing |
Teflon Tubing provides unmatched
solvent resistance for low pressure applications. |
PEEK Tubing |
PEEK can be substituted for stainless
steel tubing when contact with metal is a concern. It is inert to most HPLC
solvents, will withstand intermittent operation up to 5,000 PSI, and continuous
operation at 4,000 PSI. PEEK tubing should not be used at these pressures with
DSMO,THF, or methylene chloride. |
주문정보 |
ASI Part Number |
SS Tubing
1/16” OD x 0.010” ID x 25 ft |
800-0010 |
SS Tubing
1/16” OD x 0.020” ID x 25 ft |
800-0020 |
Teflon (TFE)
Tubing 1/16” OD x 0.030” ID x 25 ft |
810-0030 |
Teflon (TFE)
Tubing 1/8” OD x 1/16” ID x 25 ft |
810-0063 |
Teflon (TFE)
Thinwall Tubing 1/8” ID x 25 ft |
810-0125 |
PEEK Tubing
1/16” OD x 0.005” ID x 5 ft |
820-0631 |
PEEK Tubing
1/16” OD x 0.010” ID x 5 ft |
820-0632 |
PEEK Tubing
1/16” OD x 0.020” ID x 5 ft |
820-0630 | | |
|
|
|
귀하의 성공적인 연구개발의 동반자가 되겠습니다. |
*******************************************************************************************************************
(주)동방하이테크상사
http://www.allpump.co.kr
서울시 성동구 광나루로6길 35 성수이비즈센터 710호
T)02-457-6292 F)457-6293 dbht@allpump.co.kr
*******************************************************************************************************************
정량펌프, 정밀펌프, 고압펌프, 마이크로펌프, OEM 펌프, HPLC 펌프, 피스톤펌프, 주사기펌프, 실린지펌프, 다이어프램펌프, 다이아프램펌프, 튜브펌프, 튜빙펌프, 호스펌프, 연동펌프, 기어펌프, 기아펌프, 플런져펌프, 부란자펌프, 초정밀펌프, 초미세펌프, 초고압펌프, 밸브, 피팅, 튜빙, 아답터, 크로마토그래피 제품, 연구실험기자재 등