|
|
|
HPLC 부속품 |
|
[HPLC Accessories] | |
|
|
Fittings and Unions, Tubing |
|
In-Line Check Values |
|
High Pressure Metering Values |
|
Filters | | | | |
|
핏팅, 유니온 (Fittings and Unions) |
|
Universal fittings and unions are compatible with most HPLC fittings such as Parker, Swagelok, Valco, Upchurch, Beckman, and Waters, when initially assembled with new ferrules. The Waters components are direct replacements for the Waters union and fittings. All components are manufactured from 316 stainless steel, and are cleaned and passivated. Unions come complete with 1/16" compression fittings. |
|
|
Fitting |
PEEK Finger Tite Fitting for 1/16" TFE, PEEK Tube /each |
800-0630 |
Fitting |
PEEK Finger Tite Fitting for 1/16" TFE, PEEK Tube /pkg 10 |
800-0631 |
Fitting |
10-32 Compression Screw 1/16" Tube Universal /pkg 10 |
900-0622 |
Fitting |
10-32 Compression Screw 1/16" Tube Universal /pkg 25 |
900-0623 |
Fitting |
Ferrule for 1/16" Tube Universal /pkg 10 |
910-0622 |
Fitting |
Ferrule for 1/16" Tube Universal /pkg 25 |
910-0623 |
Union |
ZDV Straight Union 0.020" THRU Universal |
920-0622 |
Union |
ZDV Straight Union 0.040" THRU Universal |
920-0624 | | | |
|
튜빙(Tubing) |
|
1/16 " OD Stainless Steel Capillary ASI Capillary tubing is made from 316 stainless steel and is available in 25 ft. lengths; other lengths upon request. The tubing ID should be passivated after cutting as follows: 20 % nitric acid for 30 minutes, followed by distilled water rinse. |
|
|
Teflon (TFE) Tubing Teflon Tubing provides unmatched solvent resistance for low pressure applications. |
|
PEEK Tubing PEEK can be substituted for stainless steel tubing when contact with metal is a concern. It is inert to most HPLC solvents, will withstand intermittent operation up to 5,000 PSI, and continuous operation at 4,000 PSI. PEEK tubing should not be used at these pressures with DSMO,THF, or methylene chloride. |
|
Tubing |
SS Tubing 1/16" OD x 0.010" ID x 25 ft |
800-0010 |
Tubing |
SS Tubing 1/16" OD x 0.020" ID x 25 ft |
800-0020 |
Tubing |
Teflon (TFE) Tubing 1/16" OD x 0.030" ID x 25 ft |
810-0030 |
Tubing |
Teflon (TFE) Tubing 1/8" OD x 1/16" ID x 25 ft |
810-0063 |
Tubing |
Teflon (TFE) Thinwall Tubing 1/8" ID x 25 ft |
810-0125 |
Tubing |
PEEK Tubing 1/16" OD x 0.020" ID x 5 ft |
820-0630 |
Tubing |
PEEK Tubing 1/16" OD x 0.005" ID x 5 ft |
820-0631 |
Tubing |
PEEK Tubing 1/16" OD x 0.010" ID x 5 ft |
820-0632 | | | |
|
인라인 체크밸브 (In-Line Check Values) |
|
The ASI in-line check valve incorporates many of the innovations of our self-priming replacement check valves. It is a rapid closure cartridge valve that features very low resistance to flow, low internal volume, and operates independently of gravity. It is protected from solvent contamination by a 1/4" diameter 2 micron frit, and features crush-proof construction. The valve may be used whenever fluid flow needs to be restricted to one direction. Applications include prevention of post column derivitization fluids from back-flowing into the column in the event of mobile phase pump failure. This valve is also available in a high temperature version that will operate at up to 125º C and 5000 PSI. (Please call for more information). |
|
|
In-Line CV |
In-Line Check Valve With 1/8" Ball Cartridge |
250-2000 |
In-Line CV |
In-Line Check Valve With 1/8" Ball Cartridge, Ultra High Pressure |
250-2000UHP |
In-Line CV |
In-Line Check Valve With 3/16" Ball Cartridge |
250-2001 |
In-Line CV |
Replacement Cartridge 1/8" Ball |
250-2006 |
In-Line CV |
Replacement Cartridge 1/8" Ball, Ultra High Pressure |
250-2006UHP |
In-Line CV |
Replacement Cartridge 3/16" Ball |
250-2007 | | | |
|
고압 정량밸브 (High Pressure Metering Values) |
|
The High Pressure Adjustable Metering Valve maintains a back pressure which is directly proportional to the inlet flow rate and solvent viscosity. The valve has an adjustment range from 10 PSI to 5,000 PSI at 1.00 mL/min. with water. The dead volume is less than 4 µL with flow paths designed to minimize dispersion. |
|
|
HP Meteing Valve |
High Pressure Metering Valve |
690-0000 | | | |
|
필터 (Filters) |
|
Solvent Inlet Filters It is essential to use a solvent filter at the pump intake to insure reliable operation of the check valves and other pump system components. We recommend a 10 micron filter for most analytical applications. For flow rates in excess of 10 mL per minute, we recommend a 20 micron filter to avoid pump cavitation. ASI filters are designed to slip inside either 1/16" ID or 1/8" ID tubing, and are made from 316 stainless steel. |
|
|
In-Line Filters: Placed between the pump and injector, these filters protect the injector from pump seal wear material and extend the life of the column prefilter. All filters are made from 316 stainless steel and are rated to 6,000 psi. Filters include 10-32 compression fittings. |
|
|
Pre-Column Filters: ASI column inlet filters are designed to protect the column from injector valve and pump seal wear material. The 0.094" diameter filter cartridge offers a relatively high filtering capacity with only moderate dispersion, and is recommended for conventional 4.6 mm columns. The 0.062" diameter filter cartridge offers moderate capacity with low dispersion, and is recommended for most microbore columns. Both cartridges are replaceable and interchangeable with each other. |
|
|
Solvent Filter |
10 micron Solvent Filter for 1/16" ID /each |
850-0620 |
Solvent Filter |
10 micron Solvent Filter for 1/16" ID /pkg 5 |
850-0621 |
Solvent Filter |
20 micron Solvent Filter for 1/8" ID /each |
850-1248 |
Solvent Filter |
20 micron Solvent Filter for 1/8" ID /pkg 5 |
850-1249 |
Solvent Filter |
10 micron Solvent Filter for 1/8" ID /each |
850-1250 |
Solvent Filter |
10 micron Solvent Filter for 1/8" ID /pkg 5 |
850-1251 |
In-Line Filter |
High Capacity In-Line Filter, 2 micron |
850-1310 |
In-Line Filter |
High Capacity In-Line Filter, 0.5 micron |
850-1315 |
In-Line Filter |
2 micron Replacement Filter Cartridge for High Capacity |
850-1320 |
In-Line Filter |
0.5 micron Replacement Filter Cartridge for High Capacity |
850-1325 |
In-Line Filter |
Low Volume In-Line Filter, 2 micron x 0.25"dia. |
850-1330 |
In-Line Filter |
Low Volume In-Line Filter, 0.5 micron x 0.25"dia. |
850-1335 |
In-Line Filter |
2 micron x 0.25"dia Replacement Filterfor P/N: 850-1330 /pkg 5 |
850-1340 |
In-Line Filter |
0.5 micron x 0.25"dia. Replacement Filter for P/N: 850-1335/1355HP /pkg 5 |
850-1345 |
In-Line Filter |
0.5 micron x 0.062" Replacement Filterfor P/N: 850-1355HP-062 /pkg 5 |
850-1347 |
Precolumn Filter |
Precolumn Filter, 0.5 micron x 0.094" Filter |
850-1350 |
Precolumn Filter |
Precolumn Filter, 0.5 micron x 0.062" Filter |
850-1355 |
In-Line Filter HP |
16µL High Pressure In-Line Filter, 0.5 micron x 0.25" dia. |
850-1355HP |
In-Line Filter HP |
2µL High Pressure In-Line Filter, 0.5 micron x 0.062" dia. |
850-1355HP-062 |
Precolumn Filter |
0.5 micron x 0.094" Replacement Filter Cartridge /pkg 5 |
850-1360 |
Precolumn Filter |
0.5 micron x 0.062" Replacement Filter Cartridge /pkg 5 |
850-1365 | | | |
|
|
|
귀하의 성공적인 연구개발의 동반자가 되겠습니다. |
******************************************************************************************************************* 동방하이테크상사 http://www.allpump.co.kr 서울시 광진구 광장동 102 골든텔2-1201호 T)02-457-6292 F)457-6293 dbht@allpump.co.kr *******************************************************************************************************************
|