LSP 주입/흡입식 정밀 주사기펌프 |
|
[LSP Series Syringe
Pumps] | |
|
| | | |
|
|
|
|
|
규 격 |
+ 확대한 그림보기-> |
LSP02-1B
|
LSP10-1B
|
LSP01-1BH
|
LSP01-1C
|
Working Mode |
Infusion/Withdrawal |
Push/Full |
Channel |
2 |
10 |
1 |
2 |
Syringe |
10 uL ~ 60 mL |
10 uL ~ 10 mL |
10 uL ~ 100 mL |
10 uL ~ 10 mL |
Stroke |
140 mm |
Pusher Advance |
0.156 um/step |
Linear Speed |
5 um/min~130 mm/min |
5um/min~65mm/min |
Linear Resolution |
5 um/min |
Linear Accuracy |
≤±0.5% when ≥30% of pump stroke |
Linear Force |
≥18 kg (40 lbs) |
≥45 kg (99 lbs) |
≥9 kg (20 lbs) |
Syringe Selection |
Built-in syringe branched, size and inner diameters
|
Syringe Defined |
Can store four user-defined syringe inner
diamerters |
Flowrate Calibration |
Improve flowrate accuracy |
Running Parameter |
Infusion/withdrawal volume, infusion/withdrawal time, pause
time, etc |
Display Setting |
Display volume, flowrate or linear speed |
Power-off Memory |
Storing the running parameters automatically |
State Output |
OC gate signal to indicate start/stop and
direction |
Control Input |
Falling edge or TTL signal to control Start/Stop |
Communication |
RS-485 |
Diemensin |
280Lx210Wx140mmH |
280Lx330Wx140mmH |
280Lx250Wx140mmH |
280Lx220Wx140mmH |
Weight |
4.3 kg |
5.3 kg |
6.3 kg |
3.6 kg |
Power |
AC 90-260V/20W |
AC 90-260V/25W |
AC 90-260V/15W | |
Syringe |
Diameter (mm) |
LSP01-1A (uL/min~mL/min) |
LSP01-2A (uL/min~mL/min) |
LSP01-1BH (uL/min~mL/min) |
10 uL |
0.50 |
0.001-0.0255 |
0.001-0.0255 |
0.001-0.0128 |
25 uL |
0.80 |
0.0025-0.0653 |
0.0025-0.0653 |
0.0025-0.0327 |
50 uL |
1.10 |
0.0048-0.1235 |
0.0048-0.1235 |
0.0048-0.0618 |
100 uL |
1.60 |
0.0101-0.2614 |
0.0101-0.2614 |
0.0101-0.1307 |
250 uL |
2.30 |
0.0208-0.5401 |
0.0208-0.5401 |
0.0208-0.2701 |
500 uL |
3.25 |
0.0415-1.0784 |
0.0415-1.0784 |
0.0415-0.5392 |
1.0 mL |
4.72 |
0.0875-2.2747 |
0.0875-2.2747 |
0.0875-1.1373 |
2.0 mL |
9.00 |
0.3181-8.2702 |
0.3181-8.2702 |
0.3181-4.1351 |
5.0 mL |
13.10 |
0.6739-17.522 |
0.6739-17.522 |
0.6739-8.7608 |
10 mL |
16.60 |
1.0821-28.135 |
1.0821-28.135 |
1.0821-14.068 |
20 mL |
19.00 |
1.4176-36.859 |
- |
- |
30 mL |
23.00 |
2.0774-54.012 |
- |
- |
60 mL |
29.14 |
3.3346-86.699 |
- |
- | |
Syringe |
Diameter (mm) |
LSP01-1C (uL/min~mL/min) |
Outlet Pressure (Mpa) |
2.5 mL |
4.79 |
0.0901-2.3426 |
19.48 |
8.0 mL |
9.53 |
0.3567-9.2730 |
5.05 |
20 mL |
19.13 |
1.4371-37.3648 |
1.25 |
50 mL |
28.6 |
3.2121-83.5152 |
0.56 |
100 mL |
34.9 |
4.7831-124.361 |
0.37 | | |
|
주문정보 |
Model |
Product code |
Channel |
Pusher Advance |
Linear Force |
LSP01-1A |
050340A |
1 |
0.156 um/step |
≥9 kg (20 lbs) |
LSP01-2A |
050341A |
1 |
0.03125 um/step |
≥9 kg (20 lbs) |
LSP02-2A |
050347A |
2 |
0.03125 um/step |
≥29 kg (64 lbs) |
LSP04-1A |
050345A |
4 |
0.156 um/step |
≥18 k
Model |
Product code |
Channel |
Pusher Advance |
Linear Force |
LSP02-1B |
050344A |
2 |
0.156 um/step |
≥18 kg (40 lbs) |
LSP10-1B |
050346A |
10 |
0.156 um/step |
≥18 kg (40 lbs) |
LSP01-1BH |
050343A |
1 |
0.156 um/step |
≥45 kg (99 lbs) |
LSP01-1C |
050342A |
1 |
0.156 um/step |
≥9 kg (20
lbs) | g (40
lbs) | |
LSP01-1BH High Pressure Syringe Pump
SS syringe |
Tube length |
Stroke length |
Outer diameter |
Inner diameter |
Total length |
8 mL |
170 mm |
110.5 mm |
14 mm |
9.53 mm |
203 mm |
20 mL |
120 mm |
68.4 mm |
22 mm |
19.13 mm |
144 mm |
50 mL |
140 mm |
76.8 mm |
32 mm |
28.6 mm |
165 mm |
100 mL |
170 mm |
107.0 mm |
38 mm |
34.9 mm |
210 mm | |
LSP01-1C Push/Full Syringe Pump
| |
|
기술자료 |
LSP02(10)-1B Syringe Pump External control port (Release
Time:2017-01-06)
Pin definition
2 Directional output, OC gate output, open – infusion, close – withdrawal
(stays open when stopped) 3 COM, ground ref. 4 Gate, TTL input, change
from high to low - starts; when running stays low, change to high - stops 7
Run indicator, OC gate output, close - stopped, open – running 8 Trigger,
TTL input, falling edge start/stop pump, e.g. footswitch 9 Reverse
Direction, TTL input, normally low; change to high reverses. (Only applies to
infuse/ withdraw mode)
|
LSP02(10)-1B Syringe Pump RS485 setup (Release Time:2017-01-06)
The RS485 connections are made through terminal connectors, located on the
rear panel. A single PC can control up to 30 pumps. When controlled by a PC each
pump must be assigned an individual address. When controlled via RS485 the pump
will still respond to keypad commands. All RS485 commands settings, similar to
keypad settings, are stored in EEPROM. When RS485 is enabled, RS485 interface
will display communication address and band rate.
The communication address is from 1 to 30. The default address is 1. The band
rate is 1200 bps, 2400 bps and 9600 bps. The default band rate is 2400 bps.
RS485 format: 1 start bit, 8 data bits, 1 even parity, 1 stop. For detailed
RS485 commands please see <Longer’s RS485 Protocol for LSP>.
In parameters setting interface, press and turn RES to highlight the RS485
line. Set RS485 enabled. The LCD displays communication address and band rate.
Turn RES to make the address highlighted. Press RES to highlight the numerical
value. Turn RES to set the communication address. Press RES again to confirm and
save the setting. Turn RES to highlight the band rate. Press RES to make the
numerical value highlighted. Turn RES to select the band rate. Press RES again
to confirm and save the selection.
|
LSP02(10)-1B Syringe Pump External control function (Release
Time:2017-01-06)
External control function, including run/stop control input and direction
control input can be enabled or disabled.
1. In parameters setting interface, press and turn RES to highlight the
external control line. 2. Press RES to highlight the parameter. Turn RES to
select the needed parameter. Disable: disable the external control input,
that is, the input is invalid. TTL: TTL input controls the start and stop of
the pump. Trigger: falling edge input controls the start and stop of the
pump.
|
LSP02(10)-1B Syringe Pump Calibration (Release Time:2017-01-06)
The flowrate can be calibrated for more accurate dispense volume.
1. In parameters setting interface, press and turn RES to highlight the
Calibration line. Press RES to enter calibration interface. 2. Testing time
line is highlighted. Press RES to highlight the numerical value position. Turn
RES to select the testing time. The testing time is from 0.5 minutes to 60
hours. Press RES to confirm. 3. Press Run/Pause key to start the testing.
After testing, turn RES to highlight the testing volume line. Press RES to
highlight the numerical value position. Enter the actual volume from the
membrane keypad. Press RES to confirm. 4. After calibration, the linear speed
of the Pusher Block changes to increase the accuracy of the dispense
volume.
|
LSP02(10)-1B Dual Channels Syringe Pump Pause time setting (Release
Time:2017-01-06)
In infusion/withdrawal mode, the pause time is set in infusion parameters
setting interface. In withdrawal mode, the pause time is set in withdrawal
parameters setting interface. In continuous mode, the pause time need to be set
both in infusion mode interface and in withdrawal mode interface. The unit of
pause time is sec, i.e. second, and the range of pause time is from 0 to 9999sec
in steps of 0.1sec
|
LSP02(10)-1B Dual Channels Syringe Pump Flowrate setting (Release
Time:2017-01-06)
In parameters setting interface, turn and press RES to highlight the infusion
flowrate or withdrawal flowrate setting line. Press RES to make the numerical
value position highlighted. Enter the flowrate required from the membrane
keypad. Press RES to set flowrate unit. Turn RES to scroll through the list and
press RES to select the unit required. Possible flowrate units are µl /h, µl/m,
ml/h, ml/m. The highlighted display indicates that this parameter can be
changed.
Note: If the number entered exceeds the maximum flowrate possible then the
pump prompts the maximum feasible flowrate at the Time position. To continue
enter a flowrate smaller than the maximum.
|
LSP02(10)-1B Dual Channels Syringe Pump Volume setting (Release
Time:2017-01-06)
In parameters setting interface, turn and press RES to highlight the infusion
volume or withdrawal volume setting line. Press RES to make the numerical value
position highlighted. Enter targeted volume from the membrane keypad. Press RES
to set volume unit. Turn RES to scroll through the list and press RES to select
the unit required. Possible volume units are µl and ml, i.e. microliter and
milliliter. The highlighted display indicates that this parameter can be
changed.
Note: When the volume setting is zero, Infusion or Withdrawal modes.
Volume = 0 is interpreted as no volume and the pump will run until manually
stopped or a stall occurs. The LCD will display the flowrate
setting. Infusion/withdrawal, Withdrawal/infusion and Continuous modes. A
volume setting must be entered. If no volume is entered the motor does not
run. | |
| |
|
|
|
귀하의 성공적인 연구개발의 동반자가 되겠습니다. |
******************************************************************************************************************* (주)동방하이테크상사 http://www.allpump.co.kr 서울시 성동구 광나루로6길 35 성수이비즈센터 710호 T)02-457-6292 F)457-6293 dbht@allpump.co.kr ******************************************************************************************************************* 정량펌프, 정밀펌프, 고압펌프, 마이크로펌프, OEM 펌프, HPLC 펌프, 피스톤펌프, 주사기펌프, 실린지펌프, 다이어프램펌프, 다이아프램펌프, 튜브펌프, 튜빙펌프, 호스펌프, 연동펌프, 기어펌프, 기아펌프, 플런져펌프, 부란자펌프, 초정밀펌프, 초미세펌프, 초고압펌프, 밸브, 피팅, 튜빙, 아답터, 크로마토그래피 제품, 연구실험기자재 등
|